Siemens 5SU9306-0KK40 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9306-0KK40 SENTRON RCD/MCB, 40A Type B 6kA 1P+N

MPN5SU9306-0KK40
Active

Siemens SENTRON 5SU9 series, RCD-operated circuit breaker (RCBO), 40 A, Type B, 6 kA, 1P+N, 18 mm width unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9306-0KK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9306-0KK40 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9306-0KK40 — Mechanical
ParameterValue
Mounting positionany
Maximum0.75 W
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9306-0KK40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9306-0KK40 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens 5SU9306-0KK40 is a 1P+N RCD-operated circuit breaker (RCBO) from the SENTRON 5SU9 series, combining overcurrent protection and residual current detection in a single 18 mm wide module. The instantaneous design (no intentional delay) means it trips on the first half-cycle of a fault — suited for direct protection of final circuits where fast disconnection is required.

Supply can enter from either top or bottom, which simplifies busbar routing in a crowded panel. The IP20 rating applies once the distribution board is installed with connected conductors — treat it as a panel-internal device, not a surface-mount standalone.

Thermal behaviour and derating

At 40 °C it derates to 37.6 A, at 45 °C to 36.4 A, at 50 °C to 34.8 A, and at 55 °C to 32.4 A — a roughly 19 % reduction from 30 °C to 55 °C that must be factored into the circuit design if the enclosure runs warm.

Frequently asked questions

What conductor sizes does 5SU9306-0KK40 accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm².

Does 5SU9306-0KK40 replace 5SY3132-6 in an existing panel?

No — 5SU9306-0KK40 is a combined RCD/MCB (RCBO) with residual current detection, while 5SY3132-6 is a standard MCB without RCD functionality. They are not drop-in substitutes; the circuit design must account for the RCD element.

MPN
5SU9306-0KK40