Skip to main content
Siemens 5SU9346-1CR25 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9346-1CR25 SENTRON RCBO, 25A C-Curve 30mA 4P

MPN5SU9346-1CR25

Siemens SENTRON RCBO, 5SU9346-1CR25, 4-pole, 25 A rated, C-curve, 30 mA residual current, 6 kA breaking capacity per EN 60898.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU9346-1CR25 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU9346-1CR25 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9346-1CR25 — Mechanical
ParameterValue
Mounting positionany
Width in modular units7
Maximum75 °C
Minimum-40 °C
Width126 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9346-1CR25 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9346-1CR25 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9346-1CR25 is a SENTRON RCBO — an RCD-operated circuit breaker that combines overcurrent protection and residual current detection in one 4-pole unit. The 30 mA trip threshold covers personnel protection against direct contact in standard distribution boards.

Mounts on DIN rail, 7 modular width units wide. Feed from top or bottom — no orientation restriction. The IP20 rating applies once the distribution board is installed and conductors are connected; that's standard for enclosed panel gear. Installation depth is 70 mm into the enclosure, overall depth 77 mm including the front face. Touch protection is built in.

Rated current derates with ambient temperature: 25 A at 30 °C, 23.3 A at 40 °C, 22 A at 45 °C, 21.5 A at 50 °C, 20.8 A at 55 °C. Surge voltage resistance 4 kV. Operating frequency 50/60 Hz.

Frequently asked questions

What is the breaking capacity of 5SU9346-1CR25?

Rated breaking capacity is 6 kA according to EN 60898, which covers standard domestic and light commercial distribution board fault levels.

What is the residual current rating of this RCBO?

Tripping fault current is 30 mA, type AC — detects sinusoidal AC residual currents. Suitable for general-purpose socket-outlet and lighting circuits where DC components are not expected.

Where can I buy 5SU9346-1CR25?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation is available for 5SU9346-1CR25?

The part is halogen-free and silicon-free. It carries EN 60898 certification for the breaking capacity rating. Standard Siemens SENTRON documentation package applies.

MPN
5SU9346-1CR25