Siemens 5SU9354-7KK20 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9354-7KK20 SENTRON RCBO, 20 A, 30 mA, C-Curve, 10

MPN5SU9354-7KK20
Active

Siemens SENTRON 5SU9354-7KK20, RCBO, 1P+N, type A, 30 mA, C-characteristic, In: 20 A, Un AC: 230 V, 10 kA, 2 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9354-7KK20 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9354-7KK20 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9354-7KK20 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9354-7KK20 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9354-7KK20 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens SENTRON 5SU9354-7KK20 is a combined RCD and MCB in one 2-module-wide (36 mm) package — an RCBO protecting a single-phase final circuit. It carries a 20 A rated current with C-curve trip characteristic for moderate inrush loads (lighting banks, small motor circuits, control transformers) and integrates a 30 mA type A residual-current element for sinusoidal and pulsating DC fault currents.

The C-curve trips between 5× and 10× In, so a 20 A unit holds through the 100–200 A inrush typical of a contactor coil or a bank of LED drivers. The 30 mA type A residual element catches both sinusoidal AC faults and pulsating DC from rectified loads (variable-speed drives, switched-mode supplies) — a common requirement in modern commercial panels. The 10 kA SCCR at 230/240 V is the standard domestic and light-commercial fault level; if your point-of-supply fault current exceeds that, you need an upstream current-limiting device. The 1P+N construction switches the line pole and breaks the neutral, but the neutral pole is not overcurrent-protected — only the line pole has the thermal-magnetic trip. That is normal for single-phase RCBOs; the neutral opens with the line on a fault. The 2 MW width (36 mm) means it occupies two standard 18 mm DIN positions.

The 77 mm depth plus 70 mm installation depth leaves clearance behind a standard 80 mm deep enclosure. Ambient range -40 to 75 °C covers unheated plant rooms and outdoor-rated enclosures.

Frequently asked questions

What is the closest functional second-source to 5SU9354-7KK20?

The 5SU9354-7KK16 is the same SENTRON RCBO family with identical 10 kA breaking capacity, type A 30 mA residual, and C-curve, but rated at 16 A instead of 20 A. It drops into the same 2 MW DIN footprint and wiring scheme — no panel rework needed if the load current fits the lower rating.

Will 5SU9354-7KK20 drop into a panel specified around 5SU9354-7KK16 without rewiring?

Yes — both are 1P+N, 2 MW (36 mm) RCBOs with identical depth (77 mm), same terminal positions, and same supply connection from either top or bottom. The swap is a straight mechanical and wiring replacement as long as the 20 A rating is appropriate for the circuit.

Where can I buy 5SU9354-7KK20 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.