Siemens 5SU9354-8KK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9354-8KK10 SENTRON RCBO, 10 A D-curve, 10 kA

MPN5SU9354-8KK10
Active

Siemens SENTRON 5SU9 series, RCD-operated circuit breaker (RCBO), 1P+N, 10 A rated current, D tripping characteristic, Type A fault current, 10 kA breaking capacity acc. EN 60898 / IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU9354-8KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU9354-8KK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SU9354-8KK10 — Mechanical
ParameterValue
Mounting positionany
Maximum1.5 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU9354-8KK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU9354-8KK10 — Electrical
ParameterValue
Tripping Characteristic ClassD

Product details

What it is and what it does

The Siemens 5SU9354-8KK10 is a 1P+N RCD-operated circuit breaker (RCBO) from the SENTRON 5SU9 family. It combines overcurrent protection with residual current detection in a single 36 mm wide unit — that's two width units on a DIN rail. Rated 10 A with a D tripping characteristic, it handles high inrush loads like small motors, transformers, or solenoid banks without nuisance tripping. The Type A fault current detection catches pulsating DC residual currents, which standard AC-only RCDs miss. Breaking capacity is 10 kA per both EN 60898 and IEC 60947-2, so it clears faults up to that level without upstream coordination issues in most final-distribution panels. Ambient temperature range is -25 to +45 °C, with derating above 40 °C — at 45 °C it carries 9.1 A, at 50 °C it's 8.7 A. That's the figure to watch if the breaker sits near other heat sources in a crowded enclosure.

Mounting and wiring

Mounts on DIN rail in any position. Installation depth is 70 mm, overall depth 77 mm — that's the dimension to check against gland-plate clearance if you're retrofitting into a shallow enclosure. Terminals accept 0.75 to 35 mm² solid or stranded copper, so it handles both panel feed conductors and downstream distribution tails without adapters. Supply can land on either top or bottom terminals; no polarity restriction on the line side.

Frequently asked questions

What is the breaking capacity of 5SU9354-8KK10?

10 kA rated breaking capacity per both EN 60898 and IEC 60947-2. That covers most commercial and light industrial final-distribution fault levels without needing an upstream current-limiting device.

What wire sizes does 5SU9354-8KK10 accept?

Terminals accept 0.75 to 35 mm² solid or stranded copper conductors. That range covers everything from 1.5 mm² lighting circuits up to 10 mm² feeder tails.

Where can I buy 5SU9354-8KK10 and how is it quoted?

Sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current pricing, stock position, and factory lead time — no minimum quantity required for a quote.