Skip to main content
Siemens 5SU9356-1CR10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-1CR10 SENTRON RCBO, 10 A, 30 mA, Type C

MPN5SU9356-1CR10

Siemens SENTRON 5SU9 series, RCD-operated circuit breaker (RCBO), 2-pole (1P+N), 10 A rated, 30 mA residual current, Type C tripping characteristic, 6 kA / 10 kA breaking capacity, 2 MW width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9356-1CR10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9356-1CR10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9356-1CR10 — Mechanical
ParameterValue
Mounting positionany
Maximum25 mm²
Minimum0.75 mm²
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9356-1CR10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9356-1CR10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9356-1CR10 is a 2-pole (1P+N) RCD-operated circuit breaker — an RCBO — from the SENTRON 5SU9 series. It combines overcurrent protection and 30 mA residual current protection in a single 36 mm wide (2 MW) module, saving a DIN-rail position versus separate MCB + RCD. The 30 mA residual-current element covers personnel protection and fire prevention.

Snap-on mounting to DIN rail. Mounting position is any. Terminals accept 0.75 mm² to 25 mm² conductors. Touch protection is provided on the terminals.

Thermal derating and environmental limits

Current rating is temperature-dependent: 10 A at 30 °C, derating to 9.4 A at 40 °C, 9.1 A at 45 °C, 8.7 A at 50 °C, and 8.1 A at 55 °C. In a warm panel (40 °C+), size the load circuit accordingly — the 10 A nameplate applies only at 30 °C ambient. Halogen-free and silicon-free construction. Rated for up to 95% humidity. Overvoltage category III (fixed installation, distribution level). Energy limiting class 3 — fast enough to limit let-through energy for downstream equipment protection.

Frequently asked questions

What is the depth of 5SU9356-1CR10?

Overall depth is 77 mm; installation depth (behind panel face) is 70 mm.

What is the width of 5SU9356-1CR10?

Width is 36 mm, which is 2 modular width units (2 MW) on standard DIN rail.

MPN
5SU9356-1CR10