Skip to main content
Siemens 5SU9356-1KK06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-1KK06 SENTRON RCBO, 6A C-curve, 6kA/10kA

MPN5SU9356-1KK06
Active

Siemens SENTRON 5SU9356-1KK06, RCD-operated circuit breaker, 1P+N, 6 A, C-curve, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 2 MW wide, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9356-1KK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9356-1KK06 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9356-1KK06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9356-1KK06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9356-1KK06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9356-1KK06 is a SENTRON RCBO — an RCD-operated circuit breaker that combines overcurrent protection and residual current detection in a single 2-module-wide (36 mm) package. It's a 1P+N design, meaning it switches the line conductor and monitors the neutral, with overcurrent protection on the line pole only. The C tripping characteristic (magnetic release at 5–10× In) handles motor-starting inrush and moderate inductive loads without nuisance trips. Rated 6 A at 30 °C ambient, the part thermally derates to 5.64 A at 40 °C, 5.46 A at 45 °C, 5.22 A at 50 °C, and 4.86 A at 55 °C — a curve that matters when the breaker is packed into a warm enclosure alongside other heat sources.

Panel integration and mechanical fit

Environmental and electrical endurance

Halogen-free and silicon-free construction. The insulation voltage (Ui) is 264 V, surge voltage resistance is 4 000 V, and surge current resistance at 8/20 μS is 1 kA.

Frequently asked questions

Where can I buy 5SU9356-1KK06 and how is it quoted?

The 5SU9356-1KK06 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What is the difference between 5SU9356-1KK06 and 5SL6550-7BB?

The 5SL6550-7BB is a different class of device — a standard MCB without residual current protection. The 5SU9356-1KK06 is an RCBO that integrates both overcurrent and RCD protection in one unit. They are not drop-in substitutes; the panel wiring and protection scheme differ.

What are the key ratings of 5SU9356-1KK06?

Rated 6 A at 30 °C, C-curve, 1P+N, 6 kA per EN 60898 / 10 kA per IEC 60947-2, 2 MW wide (36 mm), depth 77 mm, operating temperature -40 °C to 75 °C.

What compliance documentation is available for 5SU9356-1KK06?

The product carries EN 60898 and IEC 60947-2 ratings. It is halogen-free and silicon-free. Specific RoHS, REACH, and UL documentation should be confirmed at quote time through the supplier.

MPN
5SU9356-1KK06