Siemens 5SU9356-1KK63 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-1KK63 SENTRON RCBO, 63A C-Curve, 6kA/10kA

MPN5SU9356-1KK63
Active

Siemens SENTRON 5SU9356-1KK63 RCBO, 1P+N, 63 A, C-curve, 6 kA per EN 60898 / 10 kA per IEC 60947-2, 2 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9356-1KK63 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9356-1KK63 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9356-1KK63 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9356-1KK63 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9356-1KK63 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9356-1KK63 is a SENTRON RCBO — a residual-current-operated circuit breaker that combines overcurrent and earth-fault protection in a single 2-module-wide (36 mm) package. It's a 1P+N design, meaning it switches and protects the line conductor only, with the neutral switched but not protected. The C-curve tripping characteristic means it holds up to 5–10× rated current for short-duration inrush (typical for motor-starting or transformer loads) before tripping magnetically. Rated 63 A at 30 °C ambient, it derates to 59.22 A at 40 °C, 57.33 A at 45 °C, 54.81 A at 50 °C, and 51.03 A at 55 °C. That derating curve matters when you're packing this into a warm enclosure — the 40 °C figure is the one to design to for a standard panel. The higher 10 kA figure gives you headroom for industrial distribution boards with higher prospective fault currents.

Installation depth is 70 mm. Mounting position is any orientation. Supply can come from either top or bottom — no mandatory orientation for the line feed.

Frequently asked questions

What is the breaking capacity of 5SU9356-1KK63?

6 kA per EN 60898 and 10 kA per IEC 60947-2. The IEC 60947-2 rating is the one to use for industrial panel coordination.

What is the width of 5SU9356-1KK63 in modular units?

2 modular width units, which is 36 mm. That's the standard footprint for a 1P+N RCBO in the SENTRON range.

Where can I buy 5SU9356-1KK63?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the temperature derating for 5SU9356-1KK63?

Rated 63 A at 30 °C, derated to 59.22 A at 40 °C, 57.33 A at 45 °C, 54.81 A at 50 °C, and 51.03 A at 55 °C. The 40 °C figure is the practical design limit for a standard enclosure.