Siemens 5SU9356-1KN20 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-1KN20 SENTRON RCBO, 2-pole 20A C-curve 30mA

MPN5SU9356-1KN20
Active

Siemens SENTRON 5SU9356-1KN20, RCBO, 2-pole 1P+N, 20 A, C-curve, 30 mA Type AC residual current, 6 kA / 10 kA breaking capacity.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9356-1KN20 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9356-1KN20 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9356-1KN20 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9356-1KN20 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9356-1KN20 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value20 A

Product details

The Siemens 5SU9356-1KN20 is a SENTRON RCBO — a combined RCD and MCB in one 2-module-wide unit. It protects a single-phase final subcircuit against overload, short-circuit, and earth leakage in one compact package. The 30 mA Type AC residual current detection catches sinusoidal AC fault currents, and the C-curve magnetic trip handles moderate inrush from motorized or capacitive loads.

Rated current is 20 A at 30 °C, derated to 18.8 A at 40 °C and 16.2 A at 55 °C — the thermal curve matters if the RCBO sits in a crowded enclosure or near a heat source. The C-curve (5–10× In magnetic release) suits mixed resistive-inductive loads like small motors, pumps, and lighting ballasts. Type AC residual current means it detects sinusoidal AC faults only; for pulsed DC or smooth DC fault currents you need Type A or F. The 1P+N switching arrangement breaks the phase and switches the neutral, common for single-phase final circuits in TN and TT systems.

Depth is 77 mm, installation depth 70 mm — check the enclosure door clearance if using a shallow consumer unit. IP20 with the distribution board installed and conductors connected; not rated for wet or washdown environments.

Frequently asked questions

What is the breaking capacity of 5SU9356-1KN20?

6 kA per EN 60898 and 10 kA per IEC 60947-2 — the higher IEC figure applies when the RCBO is used in industrial distribution per that standard.

What is the residual current rating and type?

30 mA, Type AC — detects sinusoidal AC fault currents only. For pulsed or smooth DC faults, specify Type A or F.

Where can I buy 5SU9356-1KN20?

Sourced and quoted to order against an RFQ through independent distribution. Submit a request with your target quantity and delivery window for a current price and availability check.