Siemens 5SU9356-1KX06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-1KX06 SENTRON RCBO, 6A, 30mA, Type C, 6kA

MPN5SU9356-1KX06
Active

Siemens SENTRON 5SU9356-1KX06, RCBO, 1P+N, 6 A, 30 mA, Type C, 6 kA, 2 MW, halogen-free, silicon-free.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU9356-1KX06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU9356-1KX06 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SU9356-1KX06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU9356-1KX06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU9356-1KX06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9356-1KX06 is a SENTRON RCBO — a combined residual-current device and miniature circuit breaker in a single 2-module-wide (36 mm) package. It protects a single-phase final subcircuit against both overload/short-circuit (6 A, Type C characteristic, 6 kA breaking capacity per EN 60898) and earth leakage (30 mA, Type AC residual current). The 1P+N design switches the live conductor and disconnects the neutral; the protected pole is the live side. This unit is rated for 50/60 Hz networks with an insulation voltage of 264 V and overvoltage category III, making it suitable for fixed-installation distribution boards in residential or light commercial panels. The 30 mA trip threshold covers basic shock protection and fire prevention for general-purpose socket outlets and lighting circuits.

Temperature derating and installation constraints

The 6 A rating holds at 30 °C ambient; at 40 °C it derates to 5.64 A, at 45 °C to 5.46 A, at 50 °C to 5.22 A, and at 55 °C to 4.86 A. If the distribution board runs warm — say, tightly packed with downstream loads — the effective continuous current is lower than the label value. Account for the derating curve when sizing the circuit. Mounting position is unrestricted, and the supply can enter from either the top or bottom. The unit occupies 2 modular width units (36 mm) on a DIN rail; installation depth is 70 mm, overall depth 77 mm. Pollution degree 2 applies (non-conductive pollution only, occasional condensation). The enclosure rating is IP20, conditional on the distribution board being installed with conductors connected. That means the RCBO itself is touch-safe only when mounted inside a closed panel — it is not rated for exposed or outdoor installation.

Frequently asked questions

What is the breaking capacity of 5SU9356-1KX06?

The rated breaking capacity is 6 kA per EN 60898.

What is the residual current rating of 5SU9356-1KX06?

The rated residual tripping current is 30 mA, Type AC (sinusoidal AC earth faults only).

What is the tripping characteristic of 5SU9356-1KX06?

It has a Type C tripping characteristic, meaning magnetic trip between 5 and 10 times rated current — suitable for circuits with moderate inrush, such as small motors or fluorescent lighting.

How do I get current pricing and availability for 5SU9356-1KX06?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation.

What compliance documentation does Siemens provide for 5SU9356-1KX06?

The part is halogen-free and silicon-free, and carries the EN 60898 rating for breaking capacity. Full RoHS and REACH declarations are available from Siemens documentation for the SENTRON series.