Siemens 5SU9356-1KX10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-1KX10 SENTRON RCBO, 10A, 30mA, Type AC, 6kA

MPN5SU9356-1KX10
Active

Siemens SENTRON 5SU9356-1KX10, RCD-operated circuit breaker, 2-pole, 10 A rated, 30 mA residual current, Type AC, Class C trip characteristic, 6 kA per EN 60898, 10 kA per IEC 60947-2.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9356-1KX10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9356-1KX10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9356-1KX10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9356-1KX10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9356-1KX10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9356-1KX10 is a 2-pole RCD-operated circuit breaker (RCBO) from the SENTRON family, combining overcurrent protection and residual current detection in a single 36 mm wide, 2-module-width unit. Breaking capacity is 6 kA per EN 60898 for domestic/commercial distribution boards, and 10 kA per IEC 60947-2 for industrial panel applications — the higher figure gives you coordination headroom in a sub-distribution board with a 10 kA prospective fault level.

Thermal derating and installation

The 10 A rating holds at 30 °C ambient; above that, derate to 9.4 A at 40 °C, 9.1 A at 45 °C, 8.7 A at 50 °C, and 8.1 A at 55 °C. In a sealed, high-fill panel near other heat sources, use the 40 °C column for realistic continuous load planning.

Halogen-free and silicon-free construction supports compliance with low-smoke, zero-halogen material requirements common in rail, marine, and public-building installations. The product is classified per IEC 81346-2 and DIN EN 61346-2 as function F (protection).

Frequently asked questions

What is the breaking capacity of 5SU9356-1KX10?

6 kA per EN 60898 and 10 kA per IEC 60947-2 — the higher figure is the one to use for industrial panel SCCR calculations.

What is the residual current rating and type?

30 mA, Type AC — detects sinusoidal AC fault currents only. Not suitable for circuits with VFDs, UPS, or LED drivers that can generate pulsed or smooth DC fault currents.

Where can I buy 5SU9356-1KX10?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Contact us with your target quantity and delivery window for a current quote.