Siemens 5SU9356-7CN06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-7CN06 SENTRON RCBO, 1P+N, 6A, C-Char, 30mA

MPN5SU9356-7CN06

Siemens SENTRON 5SU9356-7CN06 RCBO, 1P+N, Type A, 30 mA, C characteristic, In: 6 A, Un AC: 230 V, 6 kA per EN 60898, 10 kA per IEC 60947-2.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU9356-7CN06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU9356-7CN06 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SU9356-7CN06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU9356-7CN06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU9356-7CN06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What this RCBO is and what it protects

The Siemens SENTRON 5SU9356-7CN06 is a combined residual-current circuit breaker with overcurrent protection (RCBO) in a 1P+N, 2-module-width package. It integrates a Type A RCD (30 mA trip threshold) and a C-characteristic MCB (6 A rated current) into one DIN-rail unit, saving a slot over separate devices. The C curve means it handles moderate inrush — typical for motor starters, contactor coils, and small transformers — without nuisance tripping on startup. Breaking capacity is rated 6 kA per EN 60898 for domestic/commercial distribution boards and 10 kA per IEC 60947-2 for industrial panel applications. That dual rating covers most low-fault-current scenarios; if your prospective short-circuit current exceeds 10 kA at the point of installation, step up to a higher-rated device.

Mounting and wiring — panel fit

Snaps onto 35 mm DIN rail. The 36 mm width (2 MW) and 77 mm depth leave room for wiring in a standard distribution board; installation depth is 70 mm. Supply can enter from top or bottom — no forced orientation. Terminals accept up to the usual RCBO conductor sizes; verify the gland plate clearance if your enclosure is tight on depth. IP20 rating applies when installed in a distribution board with conductors connected — not for standalone outdoor use. Ambient range runs -40 °C to 75 °C, which covers unheated plant rooms and outdoor enclosures in most climates.

Frequently asked questions

What is the breaking capacity of 5SU9356-7CN06?

6 kA per EN 60898 and 10 kA per IEC 60947-2.

Where can I buy the 5SU9356-7CN06?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Will 5SU9356-7CN06 drop into a panel specified for 5SL6550-7BB?

Both are 2-MW DIN-rail RCBOs, but the 5SL6550-7BB is a different series with different breaking capacity and characteristic. Verify the panel's short-circuit rating and curve requirement before substituting.

MPN
5SU9356-7CN06