Siemens 5SU9356-7CN16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-7CN16 RCBO, 6 kA, 1P+N, Type A, 30 mA, C-Cha

MPN5SU9356-7CN16

Siemens 5SU9356-7CN16 RCBO, Icn: 6 kA, 1P+N, Type A, 30 mA, C-Char, In: 16 A, Un AC: 230 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this RCBO is and what the ratings mean

The Siemens 5SU9356-7CN16 is a combination residual current circuit breaker with overcurrent protection (RCBO), single-pole plus neutral, rated 16 A with a C-trip characteristic and 30 mA Type A residual sensitivity. The 6 kA breaking capacity (Icn) at 230 V AC means it can safely interrupt a short-circuit fault up to that level without welding its contacts or cascading upstream — sized for standard domestic and light commercial distribution boards where the prospective fault current stays under 6 kA. Type A detection handles pulsating DC residual currents from rectified loads like washing machines, LED drivers, and small VFDs, which a plain AC type would miss. The C-curve (trips at 5–10× In) is the go-to for motor and compressor circuits where a brief inrush shouldn't nuisance-trip the RCD side.

Where it fits in the panel

This is a DIN-rail mount module, 1 module width (18 mm per pole, so 2 modules for the 1P+N form factor). Snaps into any standard TS35 rail inside a consumer unit or sub-distribution board. The neutral connects through the device internally, so no separate neutral bar link needed downstream of this RCBO — it switches and protects both line and neutral.

Frequently asked questions

Where can I buy the 5SU9356-7CN16 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What does the 6 kA breaking capacity mean for my installation?

The 6 kA Icn rating means this RCBO can safely interrupt a short-circuit fault up to 6,000 A at 230 V AC. It is sized for standard residential and light commercial distribution boards where the prospective short-circuit current at the point of installation does not exceed 6 kA.

What is the difference between Type A and Type AC RCDs, and why does this one use Type A?

Type A RCDs detect pulsating DC residual currents in addition to sinusoidal AC. Type AC only detects pure AC. This 5SU9356-7CN16 is Type A, so it is suitable for circuits with rectified loads like washing machines, LED drivers, and small VFDs that generate pulsating DC fault currents.

What compliance documentation does Siemens provide for the 5SU9356-7CN16?

The standard Siemens RCBO range carries CE marking and is designed to meet IEC/EN 61009-1. RoHS and REACH declarations are typically available in the manufacturer's documentation package. For specific compliance certificates (UL, etc.), check the Siemens Industry Online Support portal for this order code.