Siemens 5SU9356-7KK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-7KK10 SENTRON RCBO, C-curve 10A, 30mA, 2MW

MPN5SU9356-7KK10
Active

Siemens SENTRON 5SU9356-7KK10 RCBO, 1P+N, C-curve, 10 A, 30 mA, 6 kA / 10 kA, 2 modular width units, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU9356-7KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU9356-7KK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SU9356-7KK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU9356-7KK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU9356-7KK10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9356-7KK10 is a SENTRON RCBO — a combined RCD and MCB in one 2-module-wide (36 mm) package. It protects a single-phase final subcircuit against overload, short-circuit, and earth leakage. The C-curve tripping characteristic means it holds 5–10× the rated current for magnetic trips, so it suits mixed resistive-inductive loads like small motors, pumps, and lighting banks where inrush is moderate. Rated 10 A at 30 °C, it derates to 8.1 A at 55 °C — factor that into your panel thermal budget.

Breaking capacity and standards

Breaking capacity is 6 kA per EN 60898 and 10 kA per IEC 60947-2. The EN 60898 rating governs domestic and light commercial distribution boards; the IEC 60947-2 rating applies when the device is used in industrial switchgear assemblies. Overvoltage category III and pollution degree 2 confirm it for fixed-installation mains supply.

Mounting and integration

Occupies 2 modular width units (36 mm) on a DIN rail. Installation depth is 70 mm; overall depth is 77 mm. Supply can enter from top or bottom. IP20 with conductors connected and distribution board installed — standard for enclosed panel mounting. Halogen-free and silicon-free construction, which matters for clean-room or sensitive-environment installations where outgassing is a concern.

Frequently asked questions

How do I get current pricing and availability for 5SU9356-7KK10?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time.

Will 5SU9356-7KK10 drop into a panel that was specified around 5SL6220-7 without rewiring?

Physically yes — both occupy 2 modular width units (36 mm) on DIN rail. Electrically no, unless the circuit already has separate RCD protection. The 5SU9356-7KK10 integrates the RCD; the 5SL6220-7 does not. If the panel was wired for an MCB-only device, the neutral and earth connections may need re-routing to accommodate the RCBO's additional terminals.

What compliance documentation does this brand provide for 5SU9356-7KK10 (RoHS, REACH, UL, IEC)?

The part is designed to EN 60898 and IEC 60947-2. It is halogen-free and silicon-free. For specific RoHS/REACH declarations and UL listing status, request the manufacturer's compliance certificate with your RFQ — these are typically provided at order confirmation.