Siemens 5SU9356-7KK40 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-7KK40 SENTRON RCBO, 40 A, 30 mA, Type C

MPN5SU9356-7KK40
Active

Siemens SENTRON 5SU9356-7KK40, RCBO, 1P+N, 40 A, 30 mA, Type C, 6 kA, 2 MW, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU9356-7KK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU9356-7KK40 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SU9356-7KK40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU9356-7KK40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU9356-7KK40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What this RCBO is and what it does

The Siemens 5SU9356-7KK40 is an RCBO from the SENTRON family with a 40 A rated current (at 30 °C) and a 30 mA residual-current trip in a 2-module-wide (36 mm) DIN-rail housing. Breaking capacity is 6 kA per EN 60898, adequate for domestic and commercial sub-distribution where the prospective short-circuit current stays under that threshold. The 1P+N design switches the line conductor and disconnects the neutral, but does not protect the neutral against overcurrent — only the line pole is protected. This is standard for single-phase final circuits where the neutral is not overloaded.

Temperature derating — the real-world current rating

The 40 A rating holds at 30 °C ambient. At 40 °C it drops to 37.6 A, at 45 °C to 36.4 A, at 50 °C to 34.8 A, and at 55 °C to 32.4 A. If this RCBO sits in a crowded enclosure with other heat sources, the effective continuous current is lower than the nameplate. Panel builders should apply the derating curve from the datasheet when calculating fill factor and thermal load — a 40 A circuit in a 50 °C panel is actually a 34.8 A circuit. Mounting position is unrestricted, and the operating range spans -40 °C to 75 °C, so it handles outdoor enclosures in cold climates or warm indoor switchgear without issue. The IP20 rating applies only when the distribution board is installed with conductors connected — the front face is touch-safe, but the terminals are not sealed against dust ingress.