Siemens 5SU9356-7KN16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-7KN16 SENTRON RCBO, 16 A, C-curve, Type A, 6

MPN5SU9356-7KN16
Active

Siemens SENTRON 5SU9 series RCBO, RCD-operated circuit breaker, 1P+N, 16 A, C-curve, Type A, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 2-module (36 mm), 77 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9356-7KN16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9356-7KN16 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9356-7KN16 — Mechanical
ParameterValue
Mounting positionany
Maximum1.5 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9356-7KN16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9356-7KN16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9356-7KN16 is a SENTRON RCBO — an RCD-operated circuit breaker that combines overcurrent and residual-current protection in a single 1P+N unit. At 16 A and C-curve, this is a standard fast-mover for general-purpose final circuits in commercial and light-industrial panels: lighting, socket outlets, small motor loads. The Type A characteristic catches the rectified fault currents that a plain AC-sensitive RCD would miss.

Mounting position is unrestricted — installs any orientation in the enclosure. Terminals accept solid or stranded conductors from 0.75 mm² up to 35 mm², which covers everything from 1.5 mm² lighting tails to 10 mm² submain feeds. Halogen-free and silicon-free construction suits environments where outgassing matters. Supply can land on either top or bottom terminals — no mandatory orientation.

Thermal derating and environment

Derates to 15.04 A at 40 °C, 14.56 A at 45 °C, 13.92 A at 50 °C, and 12.96 A at 55 °C. If the panel runs warm, size the upstream protection accordingly. Overvoltage category III, energy limiting class 3 — standard for distribution-board installation.

Frequently asked questions

What is the depth of 5SU9356-7KN16?

77 mm overall depth, with 70 mm installation depth behind the panel face.

What wire sizes does 5SU9356-7KN16 accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm².