Siemens 5SU9356-7KN40 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-7KN40 SENTRON RCBO, 40 A, Type A, 6 kA

MPN5SU9356-7KN40
Active

Siemens SENTRON 5SU9 series, 5SU9356-7KN40 RCD-operated circuit breaker, 2-pole 1P+N, 40 A, Type A, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 2 MW width units.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU9356-7KN40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU9356-7KN40 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SU9356-7KN40 — Mechanical
ParameterValue
Mounting positionany
Maximum1.5 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU9356-7KN40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU9356-7KN40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Siemens 5SU9356-7KN40 is a SENTRON 2-pole RCBO (RCD-operated circuit breaker) rated 40 A with Type A fault current sensitivity. It combines overcurrent protection and residual current detection in a single 36 mm wide module — two width units on the DIN rail. The C tripping characteristic handles moderate inrush from motorized loads like small pumps or compressors.

Ratings & fit

Breaking capacity: 6 kA per EN 60898 for branch-circuit protection in residential or light commercial panels, and 10 kA per IEC 60947-2 for industrial distribution boards — the higher figure applies when the prospective short-circuit current exceeds 6 kA, common in factory main panels. Type A detection catches pulsating DC fault currents from electronics and single-phase rectified loads, not just pure AC sine-wave faults. Thermal derating is specified: 40 A at 30 °C, 37.6 A at 40 °C, 36.4 A at 45 °C, 34.8 A at 50 °C, 32.4 A at 55 °C. Ambient operating range -25 to +45 °C; storage -40 to +75 °C. If the panel ambient runs above 40 °C, the continuous load must be reduced accordingly — the 40 A nameplate rating is at 30 °C. Terminal capacity accepts solid or stranded conductors 0.75 to 35 mm² — covers most branch-circuit feeds up to 6 AWG. Mounting position any orientation; installation depth 70 mm, device depth 77 mm. IP20 with distribution board installed and conductors connected. Halogen-free and silicon-free construction — relevant for clean-room or semiconductor fab environments where outgassing contaminants must be avoided. Touch protection integrated on the terminals.

Frequently asked questions

What is the breaking capacity of 5SU9356-7KN40?

6 kA per EN 60898 for branch-circuit duty, and 10 kA per IEC 60947-2 for industrial panel applications. The higher 10 kA rating applies when the prospective fault current exceeds 6 kA, which is typical in factory distribution boards.

What wire sizes does 5SU9356-7KN40 accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm² — covers branch-circuit feeds up to roughly 6 AWG. The spring terminals accommodate both solid and stranded without ferrule requirement.

Where can I buy 5SU9356-7KN40?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.