Siemens 5SU9356-7KN50 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-7KN50 SENTRON RCBO, 50 A, Type A, 30 mA, 6 k

MPN5SU9356-7KN50
Active

Siemens SENTRON 5SU9 series, RCD-operated circuit breaker (RCBO), 1P+N, 50 A, Type A, 30 mA, C characteristic, 6 kA (EN 60898) / 10 kA (IEC 60947-2), 2 MW, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SU9356-7KN50 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SU9356-7KN50 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SU9356-7KN50 — Mechanical
ParameterValue
Mounting positionany
Maximum1.5 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SU9356-7KN50 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SU9356-7KN50 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What it is and what it does

The Siemens 5SU9356-7KN50 is a 1P+N RCD-operated circuit breaker (RCBO) from the SENTRON 5SU9 series, combining overcurrent protection and residual current detection in a single 36 mm wide (2 MW) module. It is rated 50 A with a C tripping characteristic and Type A fault current sensitivity, meaning it detects both sinusoidal AC and pulsating DC residual currents — the standard requirement for circuits with single-phase rectifiers, switched-mode power supplies, or variable-speed drives. The unit carries a 6 kA breaking capacity per EN 60898 and 10 kA per IEC 60947-2, covering most residential and light commercial panelboard applications.

Ratings and what they mean for the panel

The 50 A rating is the continuous current at 30 °C ambient; at 40 °C it derates to 47 A, at 45 °C to 45.5 A, at 50 °C to 43.5 A, and at 55 °C to 40.5 A. If the panel ambient runs above 30 °C, use the derated figure for the load calculation — the 50 A nameplate applies only at the reference temperature. The Type A fault current detection (30 mA typical for this class) handles residual currents from electronic loads that a simple AC type would miss. Combined with the C characteristic (magnetic trip at 5–10× In), it is suited for circuits with motor inrush or capacitive loads that would nuisance-trip a B curve. Terminals accept solid or stranded conductors from 0.75 to 35 mm², covering most branch-circuit wire sizes up to 4 AWG. The supply can enter from either top or bottom, and the unit can be mounted in any orientation — useful when panel layout forces a rotated position. Power dissipation is 1.5 W maximum, which matters for thermal budgeting in a densely populated enclosure. The unit is halogen-free and silicon-free, a requirement in some clean-room or corrosive-environment specifications.

Mounting and integration

Snap-on mounting to DIN rail EN 60715, 36 mm width (2 MW), 90 mm height, 77 mm depth (70 mm installation depth). IP20 rated when installed in a distribution board with connected conductors. Overvoltage category III, pollution degree 2 typical for fixed-installation switchgear. The unit is touch-protected per the product feature.

Frequently asked questions

What is the breaking capacity of 5SU9356-7KN50?

6 kA per EN 60898 and 10 kA per IEC 60947-2. The higher IEC figure applies when the unit is used as a circuit-breaker in industrial installations; the EN figure governs domestic-type board ratings.

What conductor sizes does 5SU9356-7KN50 accept?

Solid or stranded conductors from 0.75 to 35 mm². That covers most branch circuits up to 50 A in copper.

Where can I buy 5SU9356-7KN50?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.