Siemens 5SU9356-7KP10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-7KP10 SENTRON RCBO, 10 A, Type A, 6 kA

MPN5SU9356-7KP10
Active

Siemens SENTRON 5SU9 series, RCD-operated circuit breaker (RCBO), 1P+N, 10 A rated, Type A fault current, tripping characteristic C, 6 kA per EN 60898, 2 width units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9356-7KP10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9356-7KP10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9356-7KP10 — Mechanical
ParameterValue
Mounting positionany
Maximum1.5 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9356-7KP10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9356-7KP10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9356-7KP10 is a SENTRON RCD-operated circuit breaker — an RCBO combining overcurrent protection and residual current detection in a single 2-module (36 mm wide) package.

Energy limiting class 3 means it lets through minimal let-through energy during a fault, which helps downstream selectivity.

Rated 10 A at 30 °C ambient, the continuous current derates to 9.4 A at 40 °C, 9.1 A at 45 °C, 8.7 A at 50 °C, and 8.1 A at 55 °C. In a sealed enclosure or near heat-generating gear, the 45 °C limit is the governing constraint — above that, the derating curve applies and the 45 °C max ambient must not be exceeded.

Width 36 mm (2 width units), depth 77 mm, installation depth 70 mm. Conductor cross-section range 0.75 to 35 mm² for both solid and stranded — covers everything from 1.5 mm² lighting circuits up to 10 mm² feeder tails. Touch protection is integrated on the busbar side.

Frequently asked questions

Where can I buy 5SU9356-7KP10 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current pricing and availability.

What is the difference between 5SU9356-7KP10 and 5SL6563-7BB?

The 5SL6563-7BB is a standard MCB without residual current protection. The 5SU9356-7KP10 is an RCBO combining overcurrent and RCD (Type A) functions in one unit. They are not direct drop-in replacements; the RCBO requires a neutral connection and occupies the same 2-module width but serves a different protection role.

What is 5SU9356-7KP10's listed depth?

The overall depth is 77 mm, with an installation depth of 70 mm behind the panel surface.

What conductor sizes does 5SU9356-7KP10 accept?

Both solid and stranded conductors from 0.75 mm² up to 35 mm².

What compliance documentation does this brand provide for 5SU9356-7KP10?

The part is designed to EN 60898 and IEC 60947-2, carries overvoltage category III rating, and is halogen-free and silicon-free. Specific RoHS/REACH declarations are typically available from the manufacturer upon request.

MPN
5SU9356-7KP10