Skip to main content
Siemens 5SU9356-7KP16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-7KP16 SENTRON RCBO, 16A Type A, 6kA/10kA

MPN5SU9356-7KP16
Active

Siemens SENTRON 5SU9 RCBO, 16 A, Type A, 30 mA, 6 kA per EN 60898 / 10 kA per IEC 60947-2, 1P+N, 2-module (36 mm), tripping characteristic C.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9356-7KP16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9356-7KP16 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9356-7KP16 — Mechanical
ParameterValue
Mounting positionany
Maximum1.5 W
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9356-7KP16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9356-7KP16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9356-7KP16 is a SENTRON 5SU9-series RCBO — an RCD-operated circuit breaker combining overcurrent and residual-current protection in a single 36 mm-wide, 2-module housing. It's rated 16 A with a Type C tripping characteristic and Type A fault-current sensitivity, making it a go-to choice for final circuits in commercial and residential distribution boards where both short-circuit and earth-fault protection are needed on a single DIN-rail footprint.

The 16 A rating at 30 °C is the headline number, but the derating curve tells the real story for a warm enclosure: at 40 °C it's 15.04 A, at 45 °C it's 14.56 A, and at 55 °C it drops to 12.96 A. The EN figure governs domestic and light commercial boards; the IEC figure applies when the device is specified per the industrial standard. Either way, it's rated for the fault levels typical of a sub-distribution board fed from a transformer of up to about 630 kVA. The energy limiting class of 3 means it lets through less let-through energy (I²t) than class 1 or 2 devices — helpful for downstream cable protection. Type A residual-current detection covers sinusoidal AC faults plus pulsating DC faults up to 6 mA smooth DC — the standard for circuits with electronics, rectifiers, or single-phase drives. The instantaneous design (no intentional delay) trips within 40 ms at rated residual current, which is the norm for socket-outlet circuits where personnel protection is the goal.

Supply can enter from either top or bottom — no mandatory orientation. The terminals accept solid or stranded conductors from 0.75 mm² up to 35 mm², which covers everything from 1.5 mm² lighting circuits to 10 mm² submains. Touch protection is built in (fingertip-safe terminals per the standard). Mounting position is any — horizontal, vertical, flat — no derating required for orientation.

Frequently asked questions

What is the breaking capacity of 5SU9356-7KP16?

6 kA per EN 60898 and 10 kA per IEC 60947-2. The EN rating applies for domestic-type boards; the IEC rating applies when specified under the industrial standard.

What conductor sizes does 5SU9356-7KP16 accept?

Solid and stranded conductors from 0.75 mm² up to 35 mm².

Where can I buy 5SU9356-7KP16 and how is it quoted?

Sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no fixed stock figures or price lists are published here.

MPN
5SU9356-7KP16