Siemens 5SU9356-8CN06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9356-8CN06 SENTRON RCBO, 6A D-curve, 30mA Type A,

MPN5SU9356-8CN06

Siemens SENTRON 5SU9356-8CN06, 2-pole RCBO, 6 A rated, D characteristic, 30 mA Type A residual current, 6 kA breaking capacity per EN 60898.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9356-8CN06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9356-8CN06 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9356-8CN06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width36 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9356-8CN06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9356-8CN06 — Electrical
ParameterValue
Tripping Characteristic ClassD

Product details

The D-curve (tripping characteristic class D) means the magnetic trip fires between 10× and 20× In — so 60 to 120 A instantaneous — which is why this breaker is the go-to for motor feeders, solenoid valve banks, and UPS input circuits where startup current can hit 8–12× running load. The 30 mA trip threshold (tripping fault current rated value 30 mA) provides personal protection against direct contact; it's the standard for socket-outlet circuits in most IEC countries. Thermal derating is real on this unit: at 40 °C ambient the 6 A rating drops to 5.64 A, at 50 °C it's 5.22 A, and at 55 °C it's 4.86 A. The insulation voltage (Ui) is rated 264 V, and overvoltage category III suits fixed-installation distribution boards downstream of the main panel. Surge voltage resistance is 4000 V, which covers most industrial transient environments.

Depth is 77 mm, installation depth 70 mm — check your enclosure depth if you're retrofitting into a shallow gland box. The IP20 rating applies only when the distribution board is installed with connected conductors — this is a panel-internal device, not a weatherproof field unit. Touch protection is built in (product feature touch protection yes). Pollution degree 2 (non-conductive dust only) is typical for clean industrial or commercial environments.

MPN
5SU9356-8CN06