Siemens 5SU9404-1KK10 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU9404-1KK10 RCBO, 10 A, 10 kA, Type C, 1P+

MPN5SU9404-1KK10

Siemens SENTRON 5SU9404-1KK10, RCD-operated circuit breaker (RCBO), 10 A rated current, 10 kA breaking capacity (EN 60898), tripping characteristic C, 1P+N, 18 mm width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU9404-1KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9404-1KK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9404-1KK10 — Mechanical
ParameterValue
Mounting positionany
Maximum0.75 W
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9404-1KK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9404-1KK10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens SENTRON 5SU9404-1KK10 is an RCD-operated circuit breaker (RCBO) — it combines overcurrent protection and residual current detection in a single 18 mm wide module.

The 10 A rating is at 30 °C ambient; at 40 °C it derates to 9.4 A, at 45 °C to 9.1 A, at 50 °C to 8.7 A, and at 55 °C to 8.1 A. If the panel runs warm — common in a crowded DIN-rail enclosure — the actual continuous current the RCBO can carry without nuisance tripping is lower than the label. It is a 1P+N device (switched phase, solid neutral) that detects AC-type fault currents only — not pulsed DC or smooth DC. If the downstream load includes variable-speed drives, LED drivers, or any rectifier front end, an AC-type RCD may not trip on the residual DC content; that application calls for a Type A or Type B RCBO.

Occupies one 18 mm width unit on a standard DIN rail. The power supply can enter from either the top or bottom, which simplifies busbar alignment in pre-wired boards. Touch protection is built into the terminals. IP20 rating applies only when the distribution board is installed and conductors are connected — the RCBO itself is not splash-proof. Mounting position is unrestricted.

Frequently asked questions

How do I get pricing and availability for 5SU9404-1KK10?

This part is sourced and quoted to order against an RFQ. Submit an RFQ for current pricing and availability; the quote will reflect real-time market conditions.

What is the depth of 5SU9404-1KK10?

The overall depth is 77 mm; the installation depth (into the panel) is 70 mm.

What conductor sizes does 5SU9404-1KK10 accept?

Solid: 0.75 to 35 mm². Stranded: 0.75 to 35 mm².

Will 5SU9404-1KK10 drop into a panel specified around 5SY6008-7?

Both are 18 mm wide DIN-rail devices, so the mechanical footprint is the same. However, the 5SU9404-1KK10 is an RCBO (overcurrent + RCD), while the 5SY6008-7 is a miniature circuit breaker only. If the original design relied on a separate RCD, the RCBO replaces both in one module — but the wiring and neutral bar arrangement must be checked for the 1P+N topology.

What compliance documentation does Siemens provide for 5SU9404-1KK10?

The part carries ratings per EN 60898 and IEC 60947-2. It is halogen-free and silicon-free. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration through the RFQ process.