Siemens 5SU9604-1KK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9604-1KK10 SENTRON RCBO, 10 A, 300 mA, C-curve

MPN5SU9604-1KK10
Active

Siemens SENTRON 5SU9604-1KK10, RCD-operated circuit breaker, 1P+N, 10 A, 300 mA, C-curve, 10 kA, 1 MW width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9604-1KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9604-1KK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9604-1KK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9604-1KK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9604-1KK10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What it is and what it does

The Siemens 5SU9604-1KK10 is a SENTRON RCD-operated circuit breaker — an RCBO that combines overcurrent protection and residual current detection in a single 1-module-wide (18 mm) device. It is rated 10 A with a C tripping characteristic and a 300 mA Type AC residual current sensitivity, making it suitable for protecting final circuits against both overload/short-circuit and earth faults in residential or commercial distribution boards. The C-curve means it trips between 5× and 10× rated current — designed for circuits with moderate inrush, such as lighting banks or small motor loads. The 10 kA breaking capacity per EN 60898 covers the majority of domestic and light commercial fault levels.

Panel integration notes

Width is 18 mm (1 modular unit), depth 77 mm, height 125 mm. It snaps onto DIN rail in any mounting position. Supply can enter from top or bottom. The IP20 rating applies once installed in a distribution board with conductors connected — standard for enclosed panel use. Rated insulation voltage (Ui) is 264 V, overvoltage category III, pollution degree 2 — typical for fixed-installation switchgear. The 4 kV surge voltage resistance covers the impulse withstand expected at the service entrance.

Thermal derating and ambient range

Rated 10 A at 30 °C ambient; derates to 9.4 A at 40 °C, 9.1 A at 45 °C, 8.7 A at 50 °C, and 8.1 A at 55 °C. Operating ambient range is -40 °C to +75 °C. If the panel runs hot, factor the derating into the circuit design.

MPN
5SU9604-1KK10