Siemens 5SU9604-1KK32 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9604-1KK32 SENTRON RCBO, 32A, 10kA, 300mA, Type A

MPN5SU9604-1KK32
Active

Siemens SENTRON 5SU9604-1KK32, RCD-operated circuit breaker (RCBO), 1P+N, 32 A, 10 kA, 300 mA, Type AC, C-curve, 1 MW wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9604-1KK32 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9604-1KK32 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9604-1KK32 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9604-1KK32 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9604-1KK32 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9604-1KK32 is a 1P+N RCD-operated circuit breaker (RCBO) from the SENTRON family, combining overcurrent protection and residual current detection in a single 18 mm wide module. Rated 32 A with a 10 kA breaking capacity per EN 60898 and IEC 60947-2, it trips on both overload/short-circuit (C-curve) and earth leakage at 300 mA, Type AC. That 300 mA trip threshold means it catches sinusoidal AC fault currents to ground — standard for general-purpose socket circuits and lighting final subcircuits where DC-sensitive electronics aren't present.

One modular width unit (18 mm) on standard DIN rail. Depth 77 mm, height 125 mm, installation depth 70 mm. Mounting position any — no derating for horizontal or inverted orientation. IP20 with conductors connected, so it lives inside a distribution board or enclosure, not exposed. Touch protection built in. Supply feed from top or bottom; no forced polarity on the line side.

Derating and thermal reality

At 40 °C it's 30.08 A; at 45 °C, 29.12 A; at 50 °C, 27.84 A; at 55 °C, 25.92 A. If your panel ambient runs 50 °C, size the upstream breaker for 28 A continuous, not 32. The 75 °C maximum and -40 °C minimum cover storage and operation — the -40 °C floor matters for unheated seasonal enclosures.

Current production — no phase-out or NRND flag on this order code. No official successor listed; this is the active variant.

Frequently asked questions

What is the breaking capacity of 5SU9604-1KK32?

10 kA per both EN 60898 and IEC 60947-2, at the rated voltage and frequency.

What is the residual current rating and type?

300 mA, Type AC — it detects sinusoidal AC fault currents to ground.

What is the closest functional second-source — 5SU9304-1KK32?

The 5SU9304-1KK32 is a sibling in the same SENTRON RCBO family; the deciding difference is the residual current rating — verify your circuit's required trip threshold before substituting.

Where can I buy 5SU9604-1KK32?

Sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing confirmed at quote time.

MPN
5SU9604-1KK32