Siemens 5SU9604-1KK40 SENTRON RCBO, 40 A, 10 kA, Type C, 1P+

MPN5SU9604-1KK40
Active

Siemens SENTRON 5SU9 series, RCD-operated circuit breaker (RCBO), 40 A rated, 10 kA breaking capacity, C-curve, 1P+N, 18 mm wide, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SU9604-1KK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SU9604-1KK40 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9604-1KK40 — Mechanical
ParameterValue
Mounting positionany
Maximum0.75 W
Width18 mm
Height125 mm
Depth77 mm
Installation depth70 mm
5SU9604-1KK40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9604-1KK40 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SU9604-1KK40 is a 1P+N RCD-operated circuit breaker (RCBO) from the SENTRON 5SU9 family, combining overcurrent and residual-current protection in a single 18 mm-wide module. It's rated 40 A at 30 °C with a C tripping characteristic, meaning it handles moderate inrush from motor or lighting loads without nuisance tripping, and it clears faults up to 10 kA per EN 60898 and IEC 60947-2. The 1P+N configuration protects one live conductor and switches the neutral, so it fits single-phase final subcircuits in distribution boards.

The 40 A rating is at 30 °C ambient; at 40 °C it's 37.6 A, at 45 °C it's 36.4 A, and at 55 °C it's 32.4 A — so if your panel runs warm, you need to account for the derating. The 18 mm width (1 width unit) keeps the rail density high — 18 modules per 360 mm DIN rail.

Frequently asked questions

Where can I buy the 5SU9604-1KK40 and get a price?

We source this RCBO to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote.

Will the 5SU9604-1KK40 drop into a panel designed for the 5SU9304-1KK32?

Yes — both are 18 mm wide, 70 mm installation depth, 1P+N RCBOs from the same 5SU9 family. The 5SU9604-1KK40 is a 40 A C-curve; the 5SU9304-1KK32 is a 32 A C-curve. No rewiring of the DIN rail or enclosure is needed, just verify the load current matches the higher rating.

What is the depth of the 5SU9604-1KK40?

Overall depth is 77 mm; installation depth (behind the panel face) is 70 mm.

What conductor sizes does the 5SU9604-1KK40 accept?

Solid conductors from 0.75 to 35 mm² and stranded conductors from 0.75 to 35 mm².

What compliance documentation does Siemens provide for the 5SU9604-1KK40?

The part is halogen-free and silicon-free. It carries the EN 60898 and IEC 60947-2 ratings for breaking capacity, and it's designed to overvoltage category III. For specific RoHS/REACH/UL declarations, the manufacturer's documentation is available on request.