Siemens 5SV1316-4KK06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV1316-4KK06 SENTRON RCBO, 1P+N, 6 kA, Type F, 30 m

MPN5SV1316-4KK06
Active

Siemens SENTRON RCBO compact, 1P+N, 6 kA per EN 60898, type F, 30 mA, C6 characteristic, 1 MW wide, 5SV1316-4KK06.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV1316-4KK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV1316-4KK06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionSuper resistant K
5SV1316-4KK06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV1316-4KK06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV1316-4KK06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

RCBO compact 1P+N — type F, 30 mA, C6

It combines a 1P+N pole configuration with a C tripping characteristic, rated at 6 kA per EN 60898 and 10 kA per IEC 60947-2. The type F residual current sensitivity is 30 mA, designed for circuits where smooth DC residual currents or mixed-frequency waveforms may be present — common on variable-speed drives, washing machines, and other inverter-fed loads that a standard AC type might miss. The supply can enter from either top or bottom, and the mounting position is unrestricted.

Type F residual current detection (30 mA) is specified for circuits where smooth DC components up to 10 mA or mixed frequencies up to 1 kHz may be present. This covers single-phase inverter-fed loads (washing machines, heat pumps, some EV chargers) that a type A or AC device might not detect reliably. Energy limitation class 3 means the device limits let-through energy (I²t) to the lowest level in its class, reducing stress on downstream cables and equipment during a fault. The 3 kA surge current withstand (8/20 μs) and 4 kV surge voltage resistance confirm it survives typical lightning-induced transients without damage.

Integration notes

At 18 mm (1 MW) wide, it occupies the same footprint as a single-pole MCB, leaving room in the panel for additional circuits. The supply can be fed from top or bottom, simplifying busbar routing in pre-wired boards.

Frequently asked questions

Where can I buy 5SV1316-4KK06 and how is it quoted?

The 5SV1316-4KK06 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest functional second-source to 5SV1316-4KK06?

The Siemens 5SY4116-7CV is a related MCB in the same SENTRON family, but it is a miniature circuit breaker without residual current protection. The 5SV1316-4KK06 is an RCBO combining overcurrent and earth-leakage protection in one unit. They are not drop-in substitutes; the 5SV1316-4KK06 provides type F 30 mA RCD functionality that the 5SY4116-7CV lacks.

What compliance documentation does Siemens provide for 5SV1316-4KK06?

The 5SV1316-4KK06 is rated per EN 60898 (6 kA) and IEC 60947-2 (10 kA). It is halogen-free and silicon-free. The manufacturer provides standard declarations of conformity and CE marking; specific documentation (RoHS, REACH, UL) should be requested at quote time.