Siemens 5SV1316-6GV13 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV1316-6GV13 SENTRON RCBO, 13 A B Curve, 6/15 kA

MPN5SV1316-6GV13
Active

Siemens SENTRON RCBO, 1P+N, 13 A, B curve, 6 kA (EN 60898) / 15 kA (IEC 60947-2), 50 Hz, 1 MW wide, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV1316-6GV13 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV1316-6GV13 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SV1316-6GV13 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV1316-6GV13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV1316-6GV13 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens 5SV1316-6GV13 is a SENTRON RCBO — a combined residual-current and overcurrent protective device in one 1-module-wide (18 mm) package, 1P+N, designed for 50 Hz systems. That dual rating means it qualifies for both the standard household breaker standard and the industrial equipment standard — useful when the same panel feeds both a domestic sub-board and a machine supply.

In a typical enclosed panel at 40 °C, the continuous current drops to 12.35 A; at 50 °C it's 11.57 A; at 60 °C it's 10.79 A; at 70 °C it's 10.01 A. If your circuit load is near 13 A and the panel runs hot, you need to uprate the breaker or account for the derating — the B curve trip threshold shifts with temperature, so nuisance tripping is unlikely, but the thermal element will carry less. The derating curve is published, not guessed.

Mounting and environmental notes

IP20 with the distribution board installed and conductors connected; that's typical for enclosed panels, not for open-air use. Halogen-free and silicon-free construction, so it's suitable for clean-room or sensitive environments where outgassing matters.

Frequently asked questions

What is the breaking capacity of 5SV1316-6GV13?

6 kA per EN 60898 and 15 kA per IEC 60947-2.

What is the width of 5SV1316-6GV13 in modular units?

One modular width (18 mm).

Does 5SV1316-6GV13 replace 5SU9354-7KK16 without rewiring?

Both are 1P+N RCBOs of similar width and function, but the 5SU9354-7KK16 has a different trip characteristic and breaking capacity. Verify the specific ratings before swapping — the physical fit on DIN rail is the same, but the circuit protection parameters differ.

Where can I buy 5SV1316-6GV13?

We source and quote it to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.