Skip to main content
Siemens 5SV1316-6LK13 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV1316-6LK13 SENTRON RCBO, 1P+N, 13A, B Curve, 6kA

MPN5SV1316-6LK13
Active

Siemens SENTRON 5SV1316-6LK13 RCBO, 1-pole+N, 13 A rated at 30 °C, B tripping characteristic, 6 kA per EN 60898, 15 kA per IEC 60947-2, short-time delayed G / super resistant K design, halogen-free, silicon-free, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV1316-6LK13 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV1316-6LK13 — Identification
ParameterValue
Product designationRCBO
Product design / constructionShort-time delayed G, super resistant K
5SV1316-6LK13 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV1316-6LK13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV1316-6LK13 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens 5SV1316-6LK13 is a SENTRON RCBO — a combined residual-current and overcurrent protective device — in a 1-pole+N configuration (switching the line, monitoring the neutral) that fits a single 18 mm modular-width slot on a DIN rail.

Energy limitation class 3 means the RCBO lets through relatively low let-through energy during a fault, which helps achieve selectivity with upstream devices and reduces stress on downstream wiring.

Thermal derating and installation constraints

The 13 A rating is at 30 °C ambient; the device must be derated in warmer enclosures — at 40 °C it carries 12.35 A, at 50 °C it carries 11.57 A, and at 70 °C it carries 10.01 A. This derating curve is built into the design and should be applied when grouping multiple RCBOs in a panel to avoid nuisance tripping from internal heat buildup. IP20 protection applies when installed in a distribution board with conductors connected — the device itself is not sealed against dust ingress or moisture, so it must live inside a closed enclosure.

Environmental and compliance profile

Frequently asked questions

What is the breaking capacity of 5SV1316-6LK13?

6 kA per EN 60898 and 15 kA per IEC 60947-2.

Where can I buy 5SV1316-6LK13 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 5SV1316-6LK13 drop into a panel specified around 5SY4116-7CV without rewiring?

Both are 1-module-wide (18 mm) DIN-rail devices, so the physical footprint is the same, but 5SV1316-6LK13 is an RCBO with combined residual-current and overcurrent protection, while 5SY4116-7CV is a plain MCB — the wiring differs because the RCBO requires a neutral connection and has a test button circuit.

MPN
5SV1316-6LK13