Skip to main content
Siemens 5SV1316-7GV06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV1316-7GV06 SENTRON RCBO, 6 A, Type A, C-curve

MPN5SV1316-7GV06
Active

Siemens SENTRON RCBO, 5SV1316-7GV06, 2-pole 1P+N, 6 A rated, Type A residual current, C tripping characteristic, 10 kA IEC 60947-2, 18 mm wide.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SV1316-7GV06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SV1316-7GV06 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous

Mechanical

5SV1316-7GV06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SV1316-7GV06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SV1316-7GV06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SV1316-7GV06 is a SENTRON RCBO — residual current circuit breaker with overcurrent protection — rated 6 A at 30 °C with a C tripping characteristic and Type A residual current sensitivity. It occupies a single modular width (18 mm) on the DIN rail, making it a tight fit for densely packed sub-distribution boards where every slot counts.

The 6 A C-curve handles moderate inrush from small motor or lighting loads without nuisance tripping. Type A residual current detection covers pulsating DC faults from rectified loads — common in modern equipment with switched-mode power supplies or variable-speed drives. The 1P+N configuration switches the phase only, leaving the neutral solid; verify your distribution design expects a switched-phase, solid-neutral RCBO before specifying.

Current-production status per the manufacturer. Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Mounts in any position on a standard 35 mm DIN rail. The 77 mm depth fits flush in most enclosure depths, leaving cable management space behind the gland plate. IP20 rated with the distribution board installed and conductors connected — not for open-panel or washdown environments.

Breaking capacity: 6 kA per EN 60898 and 10 kA per IEC 60947-2. The higher IEC figure gives headroom for industrial panels with higher prospective fault currents. Derate the thermal rating when ambient exceeds 30 °C — at 50 °C the continuous current drops to 5.28 A, and at 70 °C to 4.44 A. Halogen-free and silicon-free construction suits clean manufacturing environments.

Frequently asked questions

Where can I buy 5SV1316-7GV06 and get a price?

This part is available to quote against an RFQ through our independent distribution channel. Availability and current pricing are confirmed at quote time.

What is the difference between 5SV1316-7GV06 and the peer 5SY6006-7?

The 5SY6006-7 is a Siemens SENTRON MCB (overcurrent protection only) with no residual current protection. The 5SV1316-7GV06 adds Type A RCD functionality in a 1P+N RCBO package. If your circuit requires ground-fault protection, the MCB alone will not meet the requirement.

What is the depth of 5SV1316-7GV06?

The listed depth is 77 mm with an installation depth of 70 mm. This fits standard 80 mm deep distribution boards with room for cable management.

What compliance documentation does Siemens provide for 5SV1316-7GV06?

The RCBO is designed to EN 60898 and IEC 60947-2 standards. It carries Overvoltage Category III and Pollution Degree 2 ratings. The manufacturer typically provides CE, UKCA, and EAC declarations, plus RoHS and REACH compliance documentation on request.

MPN
5SV1316-7GV06