Skip to main content
Siemens 5SV1316-7LK13 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV1316-7LK13 SENTRON RCBO, 1P+N, 13 A, 6 kA, Type A

MPN5SV1316-7LK13
Active

Siemens SENTRON 5SV1 series RCBO, 1P+N, 13 A rated at 30 °C, 6 kA breaking capacity per EN 60898, Type A fault current, tripping characteristic C, short-time delayed G / super resistant K design, 18 mm wide, IP20 with distribution board installed.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SV1316-7LK13 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SV1316-7LK13 — Identification
ParameterValue
Product designationRCBO
Product design / constructionShort-time delayed G, super resistant K

Mechanical

5SV1316-7LK13 — Mechanical
ParameterValue
Mounting positionany
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SV1316-7LK13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SV1316-7LK13 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SV1316-7LK13 is a SENTRON RCBO — a combined residual-current and overcurrent protective device — in a 1P+N configuration, rated 230 V AC, 50/60 Hz. It carries 13 A at 30 °C (thermal derating curve provided down to 10.01 A at 70 °C), with a 6 kA breaking capacity per EN 60898. The Type A fault-current sensing catches pulsating DC residual currents, and the C characteristic handles moderate inrush from motor or lighting loads. It is a short-time delayed G / super resistant K design, meaning it tolerates brief surge currents better than a standard RCBO — relevant for panels feeding compressors or pumps that start hard.

Mounts on DIN rail in any position, one width unit (18 mm wide, 77 mm deep, 90 mm high). Installation depth is 70 mm — verify gland-plate clearance inside the enclosure. Feed can enter from top or bottom. Rated IP20 only once the distribution board is installed with connected conductors; the front face is touch-safe but the terminals are not sealed against dust or moisture. This is a panel-interior device, not a field-mounted unit.

Halogen-free and silicon-free construction — relevant for clean-room or high-reliability installations where outgassing or contamination matters. Pollution degree 2 (normal industrial environment). Overvoltage category III (fixed installation downstream of the main distribution board). Energy limiting class 3.

Frequently asked questions

Where can I buy 5SV1316-7LK13 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 5SV1316-7LK13's listed depth?

Depth is 77 mm (installation depth 70 mm). Width is 18 mm (one width unit), height 90 mm.

What compliance documentation does this brand provide for 5SV1316-7LK13?

The manufacturer provides RoHS, REACH, and relevant IEC/EN compliance documentation upon request. The part carries a 6 kA breaking capacity rating per EN 60898 and is classified per DIN EN 61346-2 / 81346-2 with function code F.

MPN
5SV1316-7LK13