Siemens 5SV1613-6KK13 SENTRON RCBO, 13 A, 30 mA Type A, 2-po

MPN5SV1613-6KK13
Active

Siemens SENTRON 5SV1613-6KK13 RCBO, 2-pole, 13 A rated, 30 mA Type A residual current, B-curve, 4.5 kA (EN 60898) / 5 kA (IEC 60947-2), 18 mm wide, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV1613-6KK13 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV1613-6KK13 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SV1613-6KK13 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV1613-6KK13 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV1613-6KK13 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens SENTRON 5SV1613-6KK13 is a 2-pole residual-current circuit breaker with overcurrent protection (RCBO), combining a 13 A thermal-magnetic overcurrent trip (B-curve) and a 30 mA Type A residual-current unit in one 18 mm-wide module. It is rated for 50 Hz networks, with a breaking capacity of 4.5 kA per EN 60898 and 5 kA per IEC 60947-2. The Type A residual-current detection handles pulsating DC fault currents up to 30 mA, covering the majority of modern electronic loads (switched-mode power supplies, variable-speed drives, lighting ballasts) that a pure AC-sensitive RCD would miss.

Temperature derating — what the 13 A rating means in a warm panel

The 13 A rating holds only at 30 °C ambient. At 40 °C it derates to 12.35 A, at 50 °C to 11.57 A, and at 70 °C to 10.01 A. In a typical enclosed distribution board where internal temperatures regularly reach 45–50 °C, the effective continuous current is closer to 12 A than 13 A. Factor this into your load schedule if the RCBO sits near other heat sources or in a compact enclosure.

Occupies a single 18 mm modular-width slot on a DIN rail. The 77 mm depth and 90 mm height fit standard distribution boards; the 70 mm installation depth accounts for the rear projection behind the rail. IP20 protection applies once the distribution board is installed and conductors are connected.

Frequently asked questions

What is the rated breaking capacity of 5SV1613-6KK13?

4.5 kA per EN 60898 and 5 kA per IEC 60947-2.

What residual current types does this RCBO detect?

Type A — it detects sinusoidal AC fault currents and pulsating DC fault currents up to 30 mA.

Where can I buy 5SV1613-6KK13 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
5SV1613-6KK13