Skip to main content
Siemens 5SV1613-6KK16 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV1613-6KK16 RCBO, 16 A, 300 mA, Type A, 4.

MPN5SV1613-6KK16
Active

Siemens SENTRON RCBO, 1P+N, 16 A rated, 300 mA residual, Type A, 4.5 kA, 18 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV1613-6KK16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV1613-6KK16 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SV1613-6KK16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV1613-6KK16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV1613-6KK16 — Electrical
ParameterValue
Tripping Characteristic ClassB
Operational current / at AC / rated value16 A

Product details

What this RCBO is and what it does

The Siemens SENTRON 5SV1613-6KK16 is a 1P+N RCBO — a combined residual-current device and miniature circuit breaker in a single 18 mm wide module. It's rated 16 A with a B tripping characteristic, meaning it protects against overloads and short circuits in circuits with resistive and light inductive loads like lighting or small motor starters. The 300 mA residual-current element is Type A, so it detects sinusoidal AC faults plus pulsating DC fault currents — common in electronics-heavy circuits like VFDs, switch-mode supplies, or modern appliances. The breaking capacity is 4.5 kA per EN 60898 and IEC 60947-2, which covers most domestic and light commercial distribution boards.

Where it fits — panel and environment

At 18 mm wide (one modular unit), this RCBO snaps onto a standard DIN rail and sits in a distribution board. The depth is 77 mm with a 70 mm installation depth, so it fits most standard enclosures without bottoming out on the backplane. It's rated IP20 once installed with conductors connected — fine for enclosed panels, not for washdown or outdoor exposure. The operating temperature range is -40 °C to 75 °C, which covers unheated utility rooms and hot switchgear cabinets. Mounting position is any, so it's fine upright, sideways, or upside-down in a crowded panel. The neutral conductor is switched internally, so you don't need a separate neutral bar connection downstream.

Frequently asked questions

What is the breaking capacity of 5SV1613-6KK16?

The breaking capacity is 4.5 kA per both EN 60898 and IEC 60947-2, which is standard for domestic and light commercial distribution boards.

What is the difference between 5SV1613-6KK16 and 5SY6002-7KL?

The 5SY6002-7KL is a different class of device — a miniature circuit breaker (MCB) without residual-current protection. The 5SV1613-6KK16 is an RCBO that combines overcurrent and earth-fault protection in one module. They are not drop-in substitutes without rewiring.

Where can I buy 5SV1613-6KK16?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SV1613-6KK16