Siemens 5SV1616-1KK16 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV1616-1KK16 RCBO, 16 A, 300 mA, Type AC, C

MPN5SV1616-1KK16
Active

Siemens SENTRON RCBO, 2-pole (1P+N), 16 A rated current, 300 mA residual current, Type AC, C-curve, breaking capacity 6 kA (EN 60898) / 10 kA (IEC 60947-2), 1 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV1616-1KK16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV1616-1KK16 — Identification
ParameterValue
Product designationRCBO
Product design / constructionInstantaneous
5SV1616-1KK16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV1616-1KK16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV1616-1KK16 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value16 A

Product details

The Siemens SENTRON 5SV1616-1KK16 is a 2-pole (1P+N) residual-current circuit breaker with overcurrent protection (RCBO) rated at 16 A operational current and 300 mA residual tripping current, Type AC, with a C tripping characteristic. It's designed for 50 Hz AC systems at 230 V and fits a single modular-width unit (18 mm) on a DIN rail. The 300 mA residual sensitivity (Type AC) covers sinusoidal AC earth faults — common for general-purpose circuits where no DC or pulsating fault content is expected.

The 5SV1616-1KK16 is part of the Siemens SENTRON range, a widely used protection component line. For a BOM freeze or second-source gate, the closest functional peer is the 5SL6550-7BB — but verify the pole count, residual current, and curve before substituting, as the 5SL6550-7BB is a different variant.

Width is 18 mm (1 modular unit), depth 77 mm, height 90 mm, with an installation depth of 70 mm. The neutral conductor is switched internally (1P+N).

Frequently asked questions

How do I get current pricing and availability for 5SV1616-1KK16?

Submit an RFQ through this listing. Pricing and availability are confirmed at quote time; we source through independent distribution channels.

What is the closest functional second-source for 5SV1616-1KK16?

The 5SL6550-7BB is a functional peer in the same SENTRON family, but verify the pole count, residual current rating, and curve before substituting — they are not drop-in identical.

What are the key specs of 5SV1616-1KK16?

2-pole (1P+N) RCBO, 16 A rated current, 300 mA residual, Type AC, C-curve, breaking capacity 6 kA (EN 60898) / 10 kA (IEC 60947-2), 1 MW width (18 mm), depth 77 mm.

MPN