Skip to main content
Siemens 5SV3311-6KK12 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3311-6KK12 SENTRON RCCB, 2-pole, 16 A, 30 mA, Typ

MPN5SV3311-6KK12
Active

Siemens SENTRON 5SV3311-6KK12, 2-pole RCCB, Type A, 16 A rated, 30 mA trip sensitivity, 230 V AC, 10 kA short-circuit capacity, SIGRES variant for harsh ambient conditions.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3311-6KK12 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV3311-6KK12 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV3311-6KK12 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3311-6KK12 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3311-6KK12 is a 2-pole residual current circuit breaker (RCCB) from the SENTRON family, Type A, rated 16 A with 30 mA trip sensitivity on a 230 V AC, 50 Hz supply. It is an instantaneous-trip device — no intentional short-time delay — so it responds immediately to earth leakage currents above the threshold. This part carries the SIGRES designation for harsh ambient conditions, meaning the internal design tolerates condensation, vibration, and aggressive atmospheres better than a standard RCCB — relevant for outdoor enclosures, agricultural sheds, or unheated plant rooms. Supply can be connected from top or bottom; for SIGRES function, top feed is recommended to maintain protection even when the device is switched off. The IP20 rating applies when installed in a distribution board with conductors connected — standard for panel-internal protection, not for wet-area standalone use.

The 30 mA sensitivity is standard for personnel protection, catching leakage through the human body. Type A detection covers sinusoidal AC and pulsating DC residual currents. The part is silicon-free. Power dissipation is 0.7 W per pole at rated current.

Occupies 2 MW (36 mm) on a 60 mm grid-spaced DIN rail. The 70 mm depth fits standard 80 mm deep enclosures with clearance for wiring. The overvoltage category is III (fixed installation, distribution level), so it is rated for the transient environment of a building main panel or industrial sub-distribution board.

Frequently asked questions

What is 5SV3311-6KK12's listed depth and width?

Depth is 70 mm, width is 36 mm (2 modular width units), height is 90 mm. These dimensions match the standard SENTRON 2-pole RCCB footprint and fit a 60 mm grid-spaced DIN rail.

Will 5SV3311-6KK12 drop into a panel specified around 5SL4363-7 without rewiring?

No — the 5SL4363-7 is a 3-pole miniature circuit breaker (MCB) with a 54 mm width and different function. The 5SV3311-6KK12 is a 2-pole RCCB at 36 mm width. They are not footprint-compatible and serve different protection roles (earth leakage vs overcurrent). Stick with the specified RCCB order code.

MPN
5SV3311-6KK12