Siemens 5SV3312-6KK12 — Residual Current Breakers (RCCB/RCBO)

SENTRON 5SV3312-6KK12 RCCB, 2P, 25 A, 30 mA, Type A

MPN5SV3312-6KK12
Active

Siemens SENTRON RCCB, 5SV3312-6KK12, 2-pole, 25 A, 30 mA, Type A, instantaneous, 50 Hz, 230 V AC, DIN rail mount, IP20.

$138.91Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3312-6KK12 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV3312-6KK12 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV3312-6KK12 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3312-6KK12 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV3312-6KK12 is a 2-pole residual current circuit breaker (RCCB) rated 25 A at 230 V AC, 50 Hz, with a 30 mA trip threshold and Type A sensitivity for pulsating DC and sinusoidal AC fault currents. It is an instantaneous (non-time-delayed) design, meaning it trips without intentional delay — suited for circuits where fast disconnection is needed and selectivity with upstream devices is managed by rating rather than timing. Rated short-circuit current withstand is 10 kA, with a permissible let-through current of 5 200 A and I²t of 58 000 A²·s, giving the panel designer clear coordination data for upstream breaker selection.

Depth is 70 mm, height 90 mm — standard for a 2-pole RCCB in a SENTRON subdistribution board. Rated IP20 with conductors connected and distribution board installed. Silicon-free construction, overvoltage category III. Supply connection can be top or bottom; for the SIGRES variant (harsh ambient conditions), top feed is required to maintain function in the switched-off state.

Frequently asked questions

What are the key ratings for 5SV3312-6KK12?

2-pole, 25 A rated current at 230 V AC, 50 Hz, 30 mA trip threshold, Type A (AC and pulsating DC), instantaneous, 10 kA SCCR, 5 200 A let-through, 58 000 A²·s I²t.

What is the mounting footprint?

36 mm wide (2 modular units), 70 mm deep, 90 mm high. Mounts on DIN rail in any position.

Does the rating derate at high ambient temperatures?

No — the 25 A rating is maintained continuously from 40 °C up to 70 °C. Operating range is -25 °C to +45 °C ambient.