Skip to main content
Siemens 5SV3314-3 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3314-3 SENTRON RCCB, Type F, 40 A, 30 mA, 2-pole

MPN5SV3314-3
Active

Siemens SENTRON 5SV3314-3, 2-pole type F short-time delayed RCCB, 40 A rated, 30 mA sensitivity, 10 kA SCCR, 230 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3314-3 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV3314-3 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3314-3 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3314-3 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3314-3 is a SENTRON residual current circuit breaker (RCCB), 2-pole, type F, short-time delayed, rated 40 A with a 30 mA trip sensitivity at 230 V AC. The short-time delayed design (type F) means it tolerates brief surge currents from equipment like variable-frequency drives or EV chargers without nuisance tripping — a key distinction from instantaneous RCCBs. Its 10 kA short-circuit current rating (SCCR) matches the fault-clearing capability of a typical upstream MCB or fuse, so it can be installed downstream without requiring a separate backup fuse for SCCR coordination.

Installation Notes

Rated IP20 with connected conductors in an installed distribution board — suitable for dry indoor enclosures only, not washdown or outdoor exposure. The silicon-free construction is specified for environments where silicone outgassing could contaminate contacts or optics. The unit accepts add-on auxiliary devices for remote signaling or shunt trip.

Frequently asked questions

What is the 5SV3314-3 used for?

It is a 2-pole type F short-time delayed RCCB rated 40 A, 30 mA at 230 V AC, designed for residual current protection in circuits that may see high-frequency or surge currents (e.g., drives, EV chargers) without nuisance tripping.

What is the SCCR of the 5SV3314-3?

The short-circuit current rating is 10 kA, and the rated conditional short-circuit current per IEC 61008-1 is 0.5 kA.

Where can I buy the 5SV3314-3?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
5SV3314-3