Siemens 5SV3314-6KL — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3314-6KL SENTRON RCCB, 40A 30mA Type A, 2-Pole

MPN5SV3314-6KL
Active

Siemens SENTRON 5SV3314-6KL, 2-pole Type A RCCB, 40 A rated, 30 mA sensitivity, 230 V AC, 10 kA SCCR, DIN rail mount.

$77.64Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3314-6KL — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV3314-6KL — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV3314-6KL — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3314-6KL — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3314-6KL is a 2-pole residual current circuit breaker (RCCB) from the SENTRON family, designed for 230 V AC single-phase networks. The 10 kA short-circuit current rating (SCCR) per IEC 61008-1 means the device can withstand and interrupt fault currents up to that level without external series fusing, though a maximum permissible series fuse of 63 A is specified for backup protection if needed.

Snaps onto a 35 mm DIN rail (REG) and occupies 2 modular width units (36 mm wide). The 70 mm depth and 90 mm height are standard for SENTRON modular devices, so it fits existing distribution board layouts with 60 mm grid spacing. Mounting position is unrestricted. IP20 rated with conductors connected — suitable for enclosed distribution boards. The silicon-free construction is noted for environments where silicone outgassing can contaminate contacts or optics.

Frequently asked questions

What is the 5SV3314-6KL used for?

It is a 2-pole Type A RCCB used for residual current protection in 230 V AC single-phase circuits, rated 40 A with 30 mA sensitivity. Typical applications include distribution boards in residential, commercial, and light industrial installations where electronic loads are present.

What is the SCCR of the 5SV3314-6KL?

The short-circuit current rating is 10 kA per IEC 61008-1, with a maximum permissible series fuse of 63 A for backup protection.

Where can I buy the 5SV3314-6KL?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Siemens provide for the 5SV3314-6KL?

The device is designed to IEC 61008-1 and carries the SENTRON brand. Specific compliance documentation (RoHS, REACH, CE, UKCA, UL) should be requested at quote time as the evidence does not list individual certifications.

MPN
5SV3314-6KL