Skip to main content
Siemens 5SV3314-6LA — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3314-6LA SENTRON RCCB, 40 A, 30 mA, 2-pole

MPN5SV3314-6LA
Active

Siemens SENTRON 5SV3314-6LA, 2-pole RCCB, Type A, 40 A, 30 mA, 230 V AC, 10 kA SCCR, with thermal overload protection, instantaneous, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SV3314-6LA — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SV3314-6LA — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous

Mechanical

5SV3314-6LA — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm

Environmental

5SV3314-6LA — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3314-6LA is a SENTRON residual current circuit breaker (RCCB), 2-pole, Type A, rated 40 A with a 30 mA trip sensitivity, for 230 V AC, 50 Hz systems. It includes thermal overload protection — that's the 'with thermal overload protection' variant, so it combines ground-fault and overcurrent protection in one 2-module-width (36 mm) package. The 10 kA short-circuit current rating (SCCR) means it can safely interrupt faults up to that level without upstream damage, sized for residential and light commercial distribution boards.

Mounting and integration

Snaps onto DIN rail (REG) and can be mounted in any position — no orientation restrictions. At 36 mm wide (2 modular width units) and 70 mm deep, it fits standard 60 mm grid-spaced enclosures. Top or bottom feed is allowed, which simplifies panel wiring when the busbar arrangement isn't fixed. IP20 with connected conductors means it's protected against finger contact once wired, but it's intended for enclosed distribution boards, not open-panel washdown areas.

What the ratings mean for fit

Type A detection catches sinusoidal AC residual currents plus pulsating DC — covers most modern electronics and single-phase rectified loads. The 30 mA trip threshold is the standard for personal protection against direct contact (30 mA is the IEC limit for fibrillation risk). Instantaneous design (no short-time delay) means it trips within milliseconds on a ground fault, which is correct for final-circuit protection but won't coordinate with upstream delayed-type RCCBs if you need selectivity. Ambient range -25 °C to +45 °C covers most indoor panel environments; storage down to -40 °C. Mechanical life of 10 000 operating cycles is typical for this class — fine for distribution, not for frequent switching duty.

Frequently asked questions

Where can I buy 5SV3314-6LA?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

What compliance documentation is available for 5SV3314-6LA?

As a SENTRON device designed to IEC 61008-1, the manufacturer provides CE declaration of conformity and RoHS/REACH compliance documentation. The 10 kA SCCR is rated per IEC 61008-1. For specific UL or CSA listings, verify with the order code — this variant is primarily IEC-marketed for European and global installations.

MPN
5SV3314-6LA