Skip to main content
Siemens 5SV3316-6KK12 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3316-6KK12 SENTRON RCCB, 2-pole, 63 A, 30 mA, Typ

MPN5SV3316-6KK12
Active

Siemens SENTRON 5SV3316-6KK12 RCCB, 2-pole, Type A, In: 63 A, 30 mA, Un AC: 230 V, SIGRES (harsh ambient conditions), 10 kA SCCR, IP20, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3316-6KK12 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV3316-6KK12 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV3316-6KK12 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3316-6KK12 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3316-6KK12 is a 2-pole residual current circuit breaker (RCCB) from the SENTRON family, rated 63 A with a 30 mA trip threshold, Type A waveform sensitivity, and a 230 V AC supply. This is the SIGRES variant, meaning it is designed for harsh ambient conditions — condensation, humidity, or corrosive atmospheres where a standard RCCB would nuisance-trip or degrade.

Installation depth is 70 mm, matching the standard SENTRON RCCB footprint. The IP20 rating applies only when the distribution board is installed with connected conductors — this is a panel-interior device, not a standalone outdoor unit. Grid spacing of 60 mm aligns with standard European enclosure cutouts.

The 30 mA sensitivity is the standard threshold for personnel protection in residential and commercial final circuits — it catches leakage currents that could pass through a human body.

Frequently asked questions

Where can I buy 5SV3316-6KK12 and get current pricing?

The 5SV3316-6KK12 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price figure is published here.

What is the difference between 5SV3316-6KK12 and the 5SL4363-7 MCB?

The 5SV3316-6KK12 is a 2-pole RCCB (residual current protection) rated 63 A / 30 mA, while the 5SL4363-7 is a 3-pole miniature circuit breaker (overcurrent protection only) rated 63 A with a C characteristic. They serve different protection functions — the RCCB detects earth leakage, the MCB detects overload and short-circuit — and are often used in series, not as substitutes. The 5SL4363-7 occupies 3 MW (54 mm) versus 2 MW (36 mm) for the RCCB, so they do not share the same DIN-rail footprint.

Will 5SV3316-6KK12 drop into a panel specified around 5SL4363-7 without rewiring?

No. The 5SV3316-6KK12 is a 2-pole RCCB (36 mm wide) providing earth leakage protection, while the 5SL4363-7 is a 3-pole MCB (54 mm wide) providing overcurrent protection. They have different widths, different pole counts, and different protection functions. A panel designed for the MCB would need rewiring and a different DIN-rail layout to accommodate the RCCB.

MPN
5SV3316-6KK12