Skip to main content
Siemens 5SV3324-4 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3324-4 SENTRON RCCB Type B, 40 A, 30 mA, 2-Pole

MPN5SV3324-4
Active

Siemens SENTRON RCCB, Type B, 40 A, 30 mA, 2-pole, short-time delayed, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3324-4 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV3324-4 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3324-4 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3324-4 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV3324-4 is a Type B residual current circuit breaker (RCCB) rated for 40 A at 50/60 Hz, with a 30 mA trip threshold and a 10 kA short-circuit current rating. Its short-time delayed design (SIGRES function) allows selectivity with upstream devices, so a downstream fault clears without dropping the main feeder — useful in distribution panels where you want to isolate a branch, not the whole board.

Type B detection covers AC, pulsating DC, smooth DC, and high-frequency residual currents up to 1 kHz — that means it catches variable-speed drive leakage and UPS harmonics, not just line-frequency faults. The 30 mA trip is the standard for personnel protection (IEC 61008-1), so this unit doubles as both equipment and shock-hazard protection in the same enclosure. Supply can enter top or bottom; for the SIGRES function, keep the supply at the top so the test circuit remains powered even when the RCCB is switched off.

Frequently asked questions

What is the 5SV3324-4 used for?

It is a Type B RCCB for personnel and equipment protection in circuits with variable-speed drives, UPS systems, or other loads that generate smooth DC or high-frequency residual currents. Common in industrial distribution panels, EV charging stations, and commercial building sub-distribution.

What are the key ratings of the 5SV3324-4?

40 A rated current, 30 mA trip threshold, 10 kA short-circuit current rating, 2-pole, short-time delayed (SIGRES), Type B residual current detection, 50/60 Hz, DIN rail mount.

How do I get pricing and availability for the 5SV3324-4?

Submit an RFQ through this listing. We source through independent distribution and confirm current pricing and lead time at quote time — no stock or price figures are published here.

What compliance documentation does Siemens provide for the 5SV3324-4?

The part is designed to IEC 61008-1 (RCCB standard). RoHS and REACH declarations are standard with Siemens SENTRON products; UL and CSA listings vary by variant — confirm at order if a specific certification is required for your jurisdiction.

MPN