Siemens 5SV3342-3 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV3342-3 RCCB, 4-pole, 25 A, 30 mA, 400 V A

MPN5SV3342-3
Active

Siemens SENTRON RCCB, 4-pole, type F, short-time delayed, In: 25 A, 30 mA, Un AC: 400 V, 50/60 Hz, 10 kA SCCR, IP20, DIN rail mount.

$169.93Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3342-3 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3342-3 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3342-3 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3342-3 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV3342-3 is a 4-pole residual current operated circuit breaker (RCCB), type F, short-time delayed, rated 25 A with a 30 mA trip sensitivity on a 400 V AC supply at 50/60 Hz. Type F means it handles residual currents up to 1 kHz, covering variable-speed drives and frequency converters that generate mixed-frequency leakage — a step beyond type A for modern motor circuits. The short-time delayed design gives it selectivity with downstream devices, so a fault on a branch trips the branch breaker first, not this main RCCB.

The IEC 61008-1 rated value of 0.8 kA is the conditional short-circuit current with a series fuse; the 10 kA figure is the standalone SCCR. Mechanical service life of 10,000 operating cycles is standard for this class; it's not a switching contactor, so the cycle count reflects the RCCB's test-button and infrequent manual operation, not daily load switching.

Mounting and installation

Mounts on DIN rail (REG) in any position. Grid spacing of 60 mm matches standard distribution board cutouts. Supply connection can be top or bottom. Protection class IP20 with the distribution board installed and conductors connected — suitable for enclosed panels, not exposed outdoor mounting. The storage limits exceed operating range — handling, not running, is what those govern.

Frequently asked questions

What are the key ratings of the 5SV3342-3?

4-pole RCCB, type F, short-time delayed, rated 25 A, 30 mA trip sensitivity, 400 V AC, 50/60 Hz, short-circuit current rating 10 kA, IP20, DIN rail mount.

MPN