Siemens 5SV3346-4KK60 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3346-4KK60 SENTRON RCCB, Type B, 63A, 30mA, 4-pol

MPN5SV3346-4KK60
Active

Siemens SENTRON RCCB, 4-pole, Type B, In: 63A, 30mA, 6mA DC, Un AC: 400V, short-time delayed, DIN rail mount, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3346-4KK60 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3346-4KK60 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3346-4KK60 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3346-4KK60 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV3346-4KK60 is a 4-pole residual current circuit breaker (RCCB) rated 63 A, 30 mA, Type B, with a 6 mA DC component detection — purpose-built for mobile installations and circuits where mixed-frequency fault currents from VFDs, UPS systems, or EV chargers are present. Type B means it catches smooth DC fault currents that a standard AC/Type A device would miss, so it's the right choice for modern power-electronics-fed loads. Rated 400 V AC, 50/60 Hz, with a 10 kA short-circuit current rating (SCCR) per IEC 61008-1. The short-time delayed design (SIGRES function) provides selectivity upstream, letting a downstream fault clear before this device trips — critical for keeping the rest of the panel live during a ground fault on one branch.

Depth of 70 mm matches the common SENTRON MCB/RCCB footprint — fits existing 70 mm deep distribution boards without re-glanding. The 72 mm width (4 MW) is one slot wider than a 3-pole MCB; plan the DIN-rail fill accordingly when replacing a 3-pole device. Supply can enter top or bottom; the SIGRES function remains active even in the switched-off state when fed from the top. Silicon-free construction — suitable for applications where silicone outgassing is prohibited (paint lines, potting stations).

Frequently asked questions

What is the difference between this Type B RCCB and a standard Type A?

Type B detects smooth DC fault currents (up to 6 mA DC here) plus AC and pulsed DC. Type A catches AC and pulsed DC but not smooth DC. For circuits with VFDs, UPS, or EV charging, Type B is required for code compliance and actual protection.

Where can I buy the 5SV3346-4KK60 and what is the price?

Sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability confirmed at quote time — no stock count or price figure published here.

What are the key ratings for the 5SV3346-4KK60?

63 A rated current, 30 mA residual sensitivity, Type B (6 mA DC detection), 400 V AC, 50/60 Hz, 10 kA SCCR per IEC 61008-1, short-time delayed for selectivity.