Skip to main content
Siemens 5SV3346-6 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3346-6 SENTRON RCCB, 63 A, 30 mA, 4-pole, 400 V A

MPN5SV3346-6
Active

Siemens SENTRON RCCB, 4-pole type A, In: 63 A, 30 mA, Un AC: 400 V, 10 kA SCCR, IP20, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3346-6 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3346-6 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV3346-6 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3346-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The 4-pole type A design detects both sinusoidal AC residual currents and pulsating DC residuals up to 30 mA — the threshold for personal protection against electric shock. At 63 A continuous rating it covers most sub-distribution, lighting, and general-power circuits in commercial and industrial panels. Mounts on DIN rail (REG) in any position; the 72 mm width (4 modular units at 60 mm grid spacing) fits four pole spaces. Installation depth is 70 mm. IP20 rating applies only when the distribution board is installed with connected conductors — this is an enclosed-panel device, not a standalone weatherproof unit. The silicon-free construction suits environments where silicone outgassing can contaminate contacts or optics. Rated for 50 Hz only (not 50/60 Hz), so confirm supply frequency before specifying.

The 5SV3346-6 is an active, current-production part in the SENTRON family.

Frequently asked questions

What is the 5SV3346-6 used for?

It is a 4-pole type A residual current circuit breaker (RCCB) rated 63 A, 30 mA, 400 V AC, used for earth-leakage protection in sub-distribution and general-power circuits in commercial and industrial panels.

What is the SCCR of the 5SV3346-6?

The short-circuit current rating is 10 kA, meaning it can safely interrupt faults up to that level without cascading upstream.

Will the 5SV3346-6 fit a panel designed for the 5SL4363-7?

No — the 5SV3346-6 is a 4-pole RCCB (72 mm wide, 4 modular units), while the 5SL4363-7 is a 3-pole MCB (54 mm wide, 3 modular units). The panel's DIN rail and gland plate would need rewiring and a different pole count.

MPN
5SV3346-6