Skip to main content
Siemens 5SV3346-6LB01 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3346-6LB01 SENTRON RCCB, 63 A, 30 mA, 4-pole, Typ

MPN5SV3346-6LB01

Siemens SENTRON 5SV3 series RCCB, 4-pole, Type A, short-time delayed, In: 63 A, 30 mA, Un AC: 400 V, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3346-6LB01 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3346-6LB01 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3346-6LB01 — Mechanical
ParameterValue
Mounting positionany
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3346-6LB01 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3346-6LB01 is a 4-pole residual current circuit breaker (RCCB) from the SENTRON 5SV3 series, rated 63 A at 400 V AC with a 30 mA trip threshold. Type A detection means it catches sinusoidal AC faults plus pulsating DC fault currents — the standard for mixed-load panels with electronics, drives, or rectifiers. The short-time delayed design (labeled 'short-time delayed' in the product designation) gives it selectivity against transient leakage, so nuisance trips from capacitive inrush or surge arrestors don't drop the whole submain. Mounts on DIN rail, takes 4 width units (72 mm), and installs in any orientation.

Type A detection covers the fault signatures from single-phase rectified loads (switched-mode supplies, VFDs, UPS) that a plain AC type would miss.

DIN rail mount, 72 mm wide (4 width units), 70 mm deep. IP20 with conductors connected — install inside a distribution board with a door or cover. Finger and back-of-hand safe terminals. Silicon-free construction suits potting or conformal-coat environments.

Frequently asked questions

Where can I buy 5SV3346-6LB01 and get a price?

Sourced to order against an RFQ through independent distribution. Submit a quote request; availability and current pricing are confirmed at quote time.

What is the difference between 5SV3346-6LB01 and the 5SY4304-7CV MCB?

They are different device classes. The 5SV3346-6LB01 is a 4-pole RCCB (residual current protection, 63 A, 30 mA, Type A, short-time delayed). The 5SY4304-7CV is a 3-pole MCB (overcurrent protection only, 15 kA SCCR per IEC 60947-2, C-curve). They serve different functions in the panel — the RCCB provides earth leakage protection; the MCB provides short-circuit and overload protection. They are not drop-in substitutes.

What compliance documentation does Siemens provide for 5SV3346-6LB01?

The product is silicon-free and carries IP20 protection with connected conductors. Standard Siemens SENTRON documentation includes the declaration of conformity to relevant EU directives (Low Voltage Directive, EMC Directive) and material declarations per RoHS and REACH. Specific certificates (UL, CSA, IEC) should be verified against the specific variant — the evidence does not list third-party approvals for this exact order code.

MPN