Skip to main content
Siemens 5SV3414-6 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV3414-6 RCCB, 40 A, 100 mA, Type A, 2-Pole

MPN5SV3414-6
Active

Siemens SENTRON RCCB, 5SV3414-6, 40 A, 100 mA, Type A, 2-pole, 10 kA, 50 Hz, IP20.

$124.14Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3414-6 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV3414-6 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV3414-6 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3414-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV3414-6 is a 2-pole residual current circuit breaker (RCCB) rated for 40 A at 50 Hz, with a 100 mA trip threshold and Type A sensitivity. It handles a 10 kA short-circuit current rating and fits a standard 2-module DIN-rail footprint (36 mm wide).

The 40 A rating holds at 40 °C ambient; at 45 °C it derates to 38.1 A, and at 60 °C it drops to 28.19 A. If your panel runs warm, size the upstream breaker accordingly — the 40 A nameplate is only valid at 40 °C. Type A detection covers pulsating DC residual currents up to 100 mA, which is the standard for single-phase electronics and variable-speed drives. The instantaneous design means no intentional delay — it trips within the RCD curve, not the S-curve. Not a daily-switch application.

Snaps onto DIN rail (REG), any mounting position. Depth is 70 mm, width 36 mm (2 MW), height 90 mm. IP20 with the distribution board installed and conductors connected.

Frequently asked questions

What is the depth of the 5SV3414-6?

70 mm.

What is the width of the 5SV3414-6?

36 mm (2 modular width units).

Will 5SV3414-6 drop into a panel specified around 5SL4363-7 without rewiring?

No. The 5SL4363-7 is an MCB; the 5SV3414-6 is an RCCB. They occupy the same DIN-rail footprint (2 MW), but the wiring and protection function are different — you cannot simply swap one for the other.

What compliance documentation does Siemens provide for 5SV3414-6?

The part is designed to IEC 61008-1. Silicon-free construction is declared. RoHS/REACH status is standard for Siemens SENTRON products but is not detailed in this listing.