Siemens 5SV3444-8LA — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3444-8LA SENTRON RCCB, 4-pole, 40 A, 100 mA, sele

MPN5SV3444-8LA
Active

Siemens SENTRON selective RCCB, 4-pole, Type A, 40 A rated current, 100 mA residual, 400 V AC, 10 kA SCCR, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3444-8LA — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3444-8LA — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SV3444-8LA — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3444-8LA — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

Selective RCCB for 4-pole 400 V AC circuits

The Siemens 5SV3444-8LA is a 4-pole selective residual current circuit breaker (RCCB) from the SENTRON series, rated 40 A with a 100 mA residual operating current for 400 V AC systems at 50/60 Hz. The selective design (Type S) means it incorporates a short time delay so that downstream RCCBs trip first during a ground fault, keeping this unit as the backup — critical for maintaining supply to upstream loads in a distribution board where you want only the faulted branch isolated. The 4-pole configuration handles three-phase plus neutral, so it fits three-phase 400 V distribution where all live conductors need residual protection.

Depth is 70 mm, installation depth also 70 mm. Supply connection can be top or bottom, giving flexibility in busbar routing.

40 A rated current at 400 V AC. The 100 mA residual sensitivity is for equipment protection or as a time-delayed upstream RCCB. The selective characteristic coordinates with downstream RCCBs. Mechanical service life of 10,000 operating cycles typical. Ambient temperature range -25 °C to +45 °C operating, -40 °C storage. Silicon-free construction for applications sensitive to silicone outgassing (e.g., paint shops, electronics assembly).

Frequently asked questions

What is 5SV3444-8LA's listed depth?

The 5SV3444-8LA has a depth of 70 mm and an installation depth of 70 mm, fitting standard distribution boards with 70 mm mounting depth.

What is 5SV3444-8LA's listed width?

The 5SV3444-8LA is 72 mm wide, occupying 4 modular width units at 60 mm grid spacing on DIN rail.

Will 5SV3444-8LA drop into a panel specified around 5SL4363-7 without rewiring?

No — the 5SL4363-7 is a 3-pole miniature circuit breaker (MCB) at 54 mm wide, while the 5SV3444-8LA is a 4-pole RCCB at 72 mm wide. They serve different functions (overcurrent vs. residual current protection) and have different pole counts and widths, so a direct swap without rewiring and panel rework is not possible.