Skip to main content
Siemens 5SV3446-6LA01 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV3446-6LA01 RCCB, 63A 4P Type A, 10kA

MPN5SV3446-6LA01
Active

Siemens SENTRON 5SV3 series RCCB, 4-pole, Type A, 63 A rated, 10 kA short-circuit current rating, short-time delayed, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3446-6LA01 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3446-6LA01 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3446-6LA01 — Mechanical
ParameterValue
Mounting positionany
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3446-6LA01 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV3446-6LA01 is a 4-pole residual current circuit breaker (RCCB) from the 5SV3 series, designed for 230/400 V AC systems. It carries a 63 A rated current and a 10 kA short-circuit current rating, with Type A fault current sensitivity — meaning it detects sinusoidal AC residual currents plus pulsating DC residual currents, covering the common fault profiles in mixed-load panels with electronics, drives, or rectifiers.

At 65 °C it derates to 57.35 A, and at 70 °C to 48.84 A. The short-time delayed design (Type S / selective) provides coordination with downstream RCCBs, preventing nuisance tripping on transient leakage from connected equipment.

Depth is 70 mm — check gland-plate clearance in shallow enclosures; the 90 mm height is standard for modular devices. Supply can enter from top or bottom — no orientation restriction.

Frequently asked questions

Where can I buy the 5SV3446-6LA01 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the depth of the 5SV3446-6LA01?

The listed depth is 70 mm, which is the dimension from the DIN rail mounting surface to the front of the device — relevant for gland-plate clearance in shallow enclosures.

What conductor sizes does this RCCB accept?

It accepts solid or stranded conductors from 0.75 mm² up to 35 mm², covering standard distribution wiring sizes.

Will the 5SV3446-6LA01 drop into a panel specified for a 5SL4363-7?

The 5SL4363-7 is a Siemens MCB (miniature circuit breaker), not an RCCB. They serve different functions — the 5SV3446-6LA01 is a residual current device, while the 5SL4363-7 is an overcurrent-only breaker. They are not drop-in interchangeable; a panel specified for an MCB would need additional space and wiring for an RCCB.

MPN
5SV3446-6LA01