Siemens 5SV3642-6KL — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV3642-6KL RCCB, 4P, 25A, 300mA, Type A

MPN5SV3642-6KL
Active

Siemens SENTRON RCCB, 4-pole, 25 A, 300 mA, Type A, instantaneous, DIN rail mount.

$85.70Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3642-6KL — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3642-6KL — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV3642-6KL — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3642-6KL — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV3642-6KL is a 4-pole residual current circuit breaker (RCCB) rated for 25 A at 230/400 V AC, 50 Hz. The instantaneous design (no short-time delay) means it clears ground faults immediately, which is the right choice for circuits where selective coordination with downstream RCDs is not required.

Ratings that matter for fit

The 1 kA surge current resistance (8/20 µs wave) means it withstands lightning-induced surges without nuisance tripping, which is important for outdoor-fed circuits. At 65 °C it drops to 23.3 A, and at 70 °C to 17.6 A. If the panel runs hot, factor that in. The I²t value of 58 000 A²·s and let-through current of 5 200 A define the energy-limiting performance for coordinating with upstream overcurrent devices.

Depth is 70 mm, height 90 mm. Mounting position is any — no restriction on orientation. Supply can enter from top or bottom. The N-pole is on the left (N left variation). Silicon-free construction, which matters for potting or conformal-coating processes in sensitive environments.

Frequently asked questions

What are the key ratings I need to verify for fit?

4-pole, 25 A rated current (holds to 60 °C, derates above), 300 mA residual trip, Type A (AC + pulsating DC), 10 kA SCCR at 230/400 V, 50 Hz, instantaneous trip. DIN rail mount, 4 MW (72 mm wide).

What compliance documentation is available for this part?

The part carries an IEC 61008-1 rated value of 0.8 kA, confirming it is designed and tested to the IEC standard for residual current circuit breakers. The evidence does not list specific RoHS, REACH, UL, or other third-party certification marks, but as a current-production Siemens SENTRON component, standard EU compliance documentation (CE, UKCA) is typically provided with the shipment.

MPN