Skip to main content
Siemens 5SV3644-6BA — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3644-6BA SENTRON RCCB, 4-pole Type A, 40 A, 300 m

MPN5SV3644-6BA

Siemens SENTRON 5SV3644-6BA, 4-pole RCCB type A, In 40 A, IΔn 300 mA, Un AC 230/400 V, 10 kA SCCR, DIN rail, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3644-6BA — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3644-6BA — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV3644-6BA — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3644-6BA — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

4-pole type A RCCB — 40 A, 300 mA residual, 230/400 V

The Siemens 5SV3644-6BA is a 4-pole residual current operated circuit breaker (RCCB) from the SENTRON family, type A, rated 40 A with a 300 mA residual operating current at 230/400 V AC.

Panel integration — DIN rail, dimensions, and mounting

Snap-on DIN rail (REG) mounting. Occupies 4 modular width units at 60 mm grid spacing — 72 mm wide, 90 mm tall, 70 mm deep.

Rated at 50 Hz only (not 50/60 Hz dual-frequency). Overvoltage category III — suitable for fixed-installation distribution boards, not for downstream equipment-side protection. The device is silicon-free — relevant for automotive or electronics manufacturing environments where silicone outgassing can contaminate contact surfaces or optical assemblies.

Designed and tested according to IEC 61008-1 (residual current operated circuit-breakers without integral overcurrent protection for household and similar uses). The rated conditional short-circuit current per IEC 61008-1 is 0.8 kA (the lower value reflects the standard's test condition for the RCCB itself; the device's own SCCR of 10 kA is the withstand rating when backed by an appropriate upstream overcurrent protective device — the maximum permissible series fuse is 80 A). Supplementary devices can be installed (e.g., auxiliary switches or shunt trips). No UL, CSA, or UKCA listing is stated in the evidence; for North American or UK installations, verify local acceptance before specifying.

Frequently asked questions

Will 5SV3644-6BA drop into a panel specified around 5SL4363-7 without rewiring?

No — the 5SL4363-7 is a 3-pole miniature circuit breaker (MCB) occupying 3 width units (54 mm), while the 5SV3644-6BA is a 4-pole RCCB occupying 4 width units (72 mm). The function (overcurrent protection vs. residual current protection), pole count, and width differ; they are not drop-in interchangeable. The panel would need rewiring and a different DIN-rail slot allocation.

MPN