Siemens 5SV3644-6KK01 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3644-6KK01 RCCB, 40 A, 300 mA, 4-pole, Type A

MPN5SV3644-6KK01
Active

Siemens SENTRON 5SV3644-6KK01, 4-pole RCCB, type A, short-time delayed, In 40 A, IΔn 300 mA, Un AC 400 V, 10 kA SCCR.

$223.67Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3644-6KK01 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3644-6KK01 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3644-6KK01 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3644-6KK01 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

40 A, 300 mA, type A — what it means for the panel

The 5SV3644-6KK01: The short-time delayed characteristic (0.8 kA per IEC 61008-1) prevents nuisance tripping from transient leakage pulses common on motor-start or capacitor inrush events. Four-pole design (3P+N) covers three-phase systems with neutral — the neutral pole switches and is monitored for residual current. The 10 000 mechanical operating cycles typical service life suits it for distribution panels where switching is infrequent (quarterly test / maintenance cycles), not daily load-break duty.

DIN-rail fit and enclosure integration

Depth is 70 mm, installation depth also 70 mm, so it sits flush with the DIN rail edge; no extra rear clearance needed beyond the rail itself. Height is 90 mm. IP20 with connected conductors — the terminals are finger-safe only when the distribution board is closed; treat it as an enclosed-panel device, not a standalone outdoor unit. Supply can land top or bottom — no mandatory orientation for line/load. The test circuit requires minimum 100 V to operate, so it functions on 230/400 V systems without a separate test supply. Silicon-free construction, overvoltage category III, ambient range -25 °C to +45 °C. Storage range extends to -40 °C.

Frequently asked questions

Can 5SV3644-6KK01 be used as a main switch?

Yes, it can serve as a main switch for a sub-distribution board, provided the load does not exceed 40 A and the fault current is within the 10 kA SCCR. The RCCB provides both isolation (4-pole switching) and earth leakage protection. However, it does not provide overcurrent protection — the upstream MCB or fuse must coordinate to clear overloads and short-circuits. The short-time delayed characteristic helps with selectivity against downstream RCCBs.

MPN
5SV3644-6KK01