Siemens 5SV3644-7 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV3644-7 RCCB, Type F, 40A, 300mA, 4P

MPN5SV3644-7
Active

Siemens SENTRON selective Type F RCCB, 4-pole, 40 A rated, 300 mA residual, 10 kA SCCR, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3644-7 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3644-7 — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SV3644-7 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3644-7 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV3644-7 is a selective Type F residual-current circuit breaker (RCCB) — 4-pole, rated 40 A at AC, with a 300 mA trip threshold and a 10 kA short-circuit current rating. Selective design means it coordinates with downstream RCCBs: during a fault on a sub-circuit, this unit stays closed so only the nearest device trips, keeping the rest of the distribution board live. Type F detection handles mixed-frequency residual currents — 50 Hz fundamental plus higher harmonics from frequency converters, washing-machine drives, or EV chargers — where a standard Type A might nuisance-trip or miss the fault entirely. The 300 mA threshold is typical for fire-protection or selective main-switch applications, not personnel shock protection (30 mA is the touch-safe limit).

Any mounting position is permitted. The IP20 rating applies once the distribution board is installed with connected conductors; during panel build, keep the terminals covered. The 70 mm depth matches standard shallow enclosures — no extra gland-plate clearance needed.

Frequently asked questions

How do I get current pricing and availability for 5SV3644-7?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time — no fixed list price is published here.

Will 5SV3644-7 drop into a panel that was specified around 5SL4363-7 without rewiring?

No — 5SL4363-7 is a Type A RCCB (different residual-current detection) and a different form factor. The 5SV3644-7 is a selective Type F unit with a 300 mA trip; swapping without verifying the circuit's fault characteristics and coordination study is not recommended.

What is 5SV3644-7's listed depth?

70 mm. That is the body depth behind the panel face; no extra projection for terminals.

What is 5SV3644-7's listed width?

72 mm, which corresponds to 4 modular width units on a standard DIN-rail grid.

MPN
5SV3644-7